Dell optiplex 790 коды ошибок

Power Button

Problem Description A possible system board resource and/or hardware

Troubleshooting

Steps

LED

Power Button

Problem

Description

Troubleshooting

Steps

The computer can emit a series of beeps during start-up if the display cannot

show errors or problems. These series of beeps, called beep codes, identify

various problems. The delay between each beep is 300 ms, the delay between

74

failure has occurred.

Clear CMOS.

Disconnect all internal and external peripherals,

and restart the computer. If the computer boots,

add the peripheral cards back one by one until you

find the bad one.

If the problem persists, the system board / system

board component is faulty.

Some other failure has occurred.

Ensure that the display/monitor is plugged into a

discrete graphic card.

Ensure that all hard drives and optical drive cables

are properly connected to the system board.

If there is an error message on the screen identifying

a problem with a device ( hard drive), check the

device to make sure it is functioning properly.

If the operating system is attempting to boot from a

device (optical drive), check system setup to ensure

the boot sequence is correct for the devices installed

on your computer.

background image

Сообщения

об ошибках

Address mark not found (Адресная метка не найдена)

Описание Система

BIOS обнаружила на диске сбойный сектор или не

смогла

найти нужный сектор.

Alert! Previous attempts at booting this system have failed at checkpoint [nnnn].

For help in resolving this problem, please note this checkpoint and contact Dell

Technical Support. (Внимание! Во время предыдущих попыток загрузки
системы

происходил сбой в контрольной точке [nnnn]. Для устранения

этой

неполадки запишите код этой контрольной точки и обратитесь в

службу

технической поддержки компании Dell)

Описание По

какой-то причине компьютер не смог завершить

процедуру

загрузки три раза подряд. Обратитесь в компанию

Dell и сообщите код контрольной точки (nnnn) специалисту
службы

поддержки

Alert! Security override Jumper is installed. (Внимание! Установлена
перемычка

блокировки защиты)

Описание Установлена

перемычка MFG_MODE и функции управления

AMT отключены, пока она не снята.

Attachment failed to respond (Устройство не отвечает)

Описание Контроллер

дисковода гибких дисков или жесткого диска не

может

посылать данные на подсоединенное устройство.

Bad command or file name (Неправильная команда или неправильное
имя

файла)

Описание Проверьте

правильность написания команды, расстановки

пробелов

, а также правильность указанного пути к файлу.

Bad error-correction code (ECC) on disk read (Неправильный код
корректировки

ошибок (ECC) при чтении диска)

Описание Контроллер

дисковода гибких дисков или жесткого диска

обнаружил

неустранимую ошибку чтения.

81

Сообщения об ошибках Сообщения Об ошибках Инструкция по эксплуатации Dell OptiPlex 790

Страница 88 в инструкции по эксплуатации Dell OptiPlex 790

Причина

Сбой завершения работы системы

Звуковой сигнал

4-2-3

Причина

Сбой линии A20

Звуковой сигнал

4-2-4

Причина

Неожиданное прерывание в защищенном режиме

Звуковой сигнал

4-3-1

Причина

Сбой памяти выше адреса 0FFFFh

Звуковой сигнал

4-3-3

Причина

Ошибка счетчика 2 микросхемы таймера

Звуковой сигнал

4-3-4

Причина

Остановка часов истинного времени

Звуковой сигнал 4-4-1

Причина

Сбой проверки последовательного или параллельного порта

Звуковой сигнал

4-4-2

Причина

Сбой развертывания кода в теневую память

Звуковой сигнал

4-4-3

Причина

Сбой проверки математического сопроцессора

Звуковой сигнал

4-4-4

Причина

Сбой проверки кэша

Сообщения об ошибках

Address mark not found (Адресная метка не найдена)

Описание Система

BIOS обнаружила на диске сбойный сектор или не смогла найти нужный сектор.

background image

Code

4–3–1

Cause

Memory failure above address 0FFFFh

Code

4–3–3

Cause

Timer-chip counter 2 failure

Code

4–3–4

Cause

Time-of-day clock stopped

Code

4–4–1

Cause

Serial or parallel port test failure

Code

4–4–2

Cause

Failure to decompress code to shadowed memory

Code

4–4–3

Cause

Math coprocessor test failure

Code

4–4–4

Cause

Cache test failure

Error Messages

Address mark not found

Description The BIOS found a faulty disk sector or could not find a particular

disk sector.

Alert! Previous attempts at booting this system have failed at checkpoint [nnnn].

For help in resolving this problem, please note this checkpoint and contact Dell

Technical Support.

Description The computer failed to complete the boot routine three

consecutive times for the same error. Contact Dell and report the

checkpoint code (nnnn) to the support technician

77

Table of Contents

Dell Error Code 1 2 3

Dell error code 1 2 3  is one of the common problems faced by dell users while using a desktop or laptop. When a user faces this issue, then the laptop is unable to boot or unable to open BIOS. So, you need to fix the error code 1 2 3 as soon as possible until it affects other files.

Dell laptops are the powerful laptops that are available in the market. They are providing the best service and support to their users. Whenever user faces Error code 1 2 3 then they can contact dell computer customer care.

At dell technical support customer will get assured assistance that is required to fix the dell error. User can fix the dell error code 1 2 3 by itself. Then just need to follow the steps given below in the blog.

What are the signs of an error code 1-2-3

  • The laptop is unable to boot or unable to open BIOS
  • The power button LED blinks in a pattern of 1-2-3
  • The computer emits beeps, such as two beeps and 1-2-3 lights on
  • The RAM may not be detected or may be damaged
  • The motherboard may have failed, or there may be a chipset error
  • There may be a problem with the power supply, battery, or hard disk

Reasons Behind Dell Error code 1 2 3

There are various reasons for which you face this error, some of the reasons are as a power supply issue, motherboard issue, battery problem or hard disk issue. If you are also facing this issue then you don’t need to worry. Just read and follow the procedure step by step to fix the dell error.

4 Ways to Fix Dell Error Code 123

Method 1: Check the Power Supply

  1. Check for the Power supply connection of the laptop. Make sure the cable is connected properly and there is no problem with socket.
  2. If have any issue, then reply power cable or power source.

Method 2: Use the Dell Diagnostic Tool

This section provides information on how to use the Dell Diagnostics F12.

Dell Diagnostics F12 is a diagnostic tool that can be used to troubleshoot and fix issues with Dell computers. It can also be used to check hardware, firmware, and software configurations.

  1. When you start dell laptop and dell logo appears,  then start pressing the F12 key.
  2. If it shows that no Diagnostic utility partition is available then you need to run the diagnostic tool from the “Drivers & Utilities” media.
  3. When a list appears select “Boot to Utility Partition” and hit Enter button
  4. When Dell diagnostic “Main Menu” option appears. Select the Hard disk or any other test that you want to run.

Method 3: Check for the Ram

  1. Sometimes, Dell Error Code 1 2 3 appears just because of wrong RAM settings. Check the Ram is connected properly with the motherboard.
  2. Make sure the RAM is not damaged one or check for any bent pin that blocking RAM to connect.
  3. Make sure you are using

Method 4: Dell Support Assistant

Try to use dell support assistant to get help from an expert technician. If you are unable to fix dell error code 123 then you can contact dell computer repair. The technician at dell customer care is available 24/7 to help the user. You just need to make a call on Dell helpline USA toll-free.

The technician will check the reason behind the issue and help you to fix the problem with the best available solution. Dell Experts are Microsoft certified technicians and experience in troubleshooting common and major dell laptop or computer problems. Contact dell customer service to fix dell error code 123.

Dell diagnostic lights 1 2 3

To “Solve: Dell Error Code 1 2 3” is one of the most general issues. That end-users face as starting the task with their Dell device. The Subject is beautiful too self-explanatory about Dell Diagnostic Light 1-2-3 lights up no BEEPS. That meaning as your Dell device has three light labels on the top front panel ‘1’, ‘2’, ‘3’, therefore you can not boot the system. You can not further get to the BIOS, therefore, you can not get to the front panel.

The probable cause of this issue includes the power supply problem of the power button, motherboard problem, hard disk problem, or battery problem, etc. Therefore, if you have a few issues with your Dell Optiplex320/Dell OptiPlex 740/Dell XPS 420, or Dell laptop. You do not have to worry about it. It is important to you understand Dell Error Code 1 2 3 and what process to follow to resolve with your Dell Laptop can get you back on right track. Read the full article to solve the issue on the right path. Or you can contact the online dell customer care team skilled professionals to solve these issues.

Dell Led Codes

Dell led codes are a combination of colors and numbers that are used to identify the problem with a Dell computer.

The dell led codes can be viewed by pressing the F2 key on a Dell computer. The dell led code will be displayed on the screen in an 8-digit format.

To find the dell led codes, you need to do the following steps:

  • Power off your laptop and remove the battery.
  • Hold down the power button for 10 seconds.
  • Press and hold Volume Down and Power buttons together for a few seconds.
  • Release Volume Down and continue holding Power button until you see a Dell logo on your screen.
  • Release the power button when you see a BIOS screen.
  • Select “enter setup” by using arrow keys on your keyboard, then press Enter.
  • Next, Select “Advanced Boot Options”, then press Enter again.
  • Select “Restore Bios to Default Settings”, then press Enter again.

FAQs

What is the beep code 1-3-2 on Dell BIOS?

The 1-3-2 beep code on Dell BIOS usually indicates an issue with the motherboard. This could mean a problem with the system board or a RAM read/write failure.

What is code 123 on Dell Optiplex?

Code 123 on a Dell Optiplex typically refers to a system diagnostic light pattern of 1-2-3 (LED lights 1, 2, and 3 are on, but 4 is off). This error usually indicates a problem with the motherboard or BIOS.

What does 3 beeps mean on a Dell computer?

Three beeps usually mean there’s a problem with the system memory. It might indicate a failure in the first 64K of the memory or that the motherboard can’t read the memory.

What are the lights 1 and 3 on Dell Optiplex 790?

If lights 1 and 3 are on your Dell Optiplex 790, it indicates a problem with the memory or the motherboard. It’s recommended to troubleshoot by reseating the memory modules or testing them in another system if possible.

Dell Optiplex 780 error codes 1, 2, 3.

If your Dell Optiplex 780 displays lights 1, 2, and 3, this indicates a possible failure of the system board. A BIOS ROM checksum error has occurred, and you should seek technical assistance to resolve it.

Remember, if you experience any of these issues, it’s recommended to contact Dell Support or a certified IT professional to ensure proper and safe handling of your equipment.