Sometimes Storage Executive gets an error when trying to execute the update firmware option for an SSD within the program.
Diagnosis
There is something in the system that is interfering with Storage Executive, preventing it from intiating the restart and subsequent loading of the Linux® firmware updating boot sequence.
Solution
Depending on the nature of the error, there may be multiple fixes or workarounds. Here is a list of things you can check that may resolve problems with Storage Executive updating your firmware.
- Make sure you have the most recent version of Storage Executive installed.
- Disable any antivirus software that prevents the updater from initiating.
- Ensure that you are not using RAID mode in the system BIOS settings, RAID will often prevent many of the features in Storage Executive from working with your drive, AHCI is the preferred mode. Refer to your system manufacture for any help with this setting.
- If you are still not able to get the automated updater to work, use the manual boot file ISO for your SSD on our firmware webpage to manually execute the update.
В биосе определяется, в винде уже нет. Скачал прогу с сайта пишет что микропрограмма не доступна.
Кто что подскажет делать ?
Комментарии
7
10 месяцев назад
Изменено автором
Надпись «Микропрограмма НЕ доступна» в приложении «Crucial Storage Executive» говорит о недоступности сервера с прошивками. На закладке «Обновление встроенного ПО» в подтверждение этого Вы получите сообщение «Ошибка при проверке наличия обновлений встроенного ПО connect timed out». Для решения этой проблемы мне помог VPN (не браузерный) с установкой европейского местоположения, доступ к прошивке появился. Видимо на данный момент «Crucial» заблокировали доступ к обновлениям из России. Ещё может помешать обновлению антивирус или брандмауэр. Производитель приложения «Crucial Storage Executive» рекомендует отключить их перед проверкой обновления, в случае появления подобной ошибки.
Если прошивка SSD актуальная, то будет другое сообщение «Установлена последняя версия». как в моих скриншотах.
В биосе определяется, в винде уже нет. Скачал прогу с сайта пишет что микропрограмма не доступна.
И в винде все определяется, о чем косвенно говорит тот факт, что накопитель виден фирменной прогой Storage Executive. Недоступность микропрограммы это о том, что для вашего SSD (поскольку модель старая) нет более новой версии, поэтому она не доступна. Что делать вам уже написали.
Свернуть ответы 1
10 месяцев назад
Изменено модератором
Вы ошиблись, в случае отсутствия обновления микропрограммы будет другая надпись «Установлена последняя версия».
11 месяцев назад
Изменено автором
в винде уже нет.
в управление дисками зайдите, создайте разметку и букву тома на накопителе
Свернуть ответы 1
в винде уже нет
Создай том через панель управления — администрирование — управление компьютером — управление дисками.
Свернуть ответы 1
Обсуждение товара
DRam кэш на серии ssd mx500
Почему нет dram кэша? Вроде его нет на bx500 серии. Какой тип памяти tls или qls? Какая версия микроконтроллера, вроде ставят 2259?
Можно ли этот ssd использовать как основной?
У меня есть старый ноут но у него нет двд привода или м2 куда я бы мог вставить этот ssd. И тут встает вапрос нормально ли будет работать ssd под нагрузкой винды и всех рабочих программ и игр?
Question Crucial MX500 Firmware Error — Drive works but cant do anything in Storage Executive
-
Thread starterphanco
-
Start date
You should upgrade or use an alternative browser.
-
- Apr 5, 2022
-
- 5
-
- 0
-
- 10
-
#1
I have 3 Crucial drives in my PC, 1TB NVME, 1TB MX500 SATA and 500GB MX500 SATA. Planned to move the 500GB into Son’s PC as he needed some additional storage. Launched Crucial Storage Exec (CSE) and it stated that the drive had a firware error. I could view the drive, but immediately after viewing it would disappear from the drive list in CSE (but was still fully operational in windows). Contacted crucial and gave lots of info. I cant email them stuff as they reject my Hotmail account as SPAM! so had to use twitter support on a 24 hour turnaround — but basically they have nothing to offer…
Things I have tried :
- Uninstall AHCI driver (standard windows one) and reboot to reinstall driver — no difference
- swap SATA port with the 1TB drive that is ok -> no difference
- delete and re-install CSE -> no difference
- remove drive into a usb caddy -> no longer reports firmware error, but cant run self test in CSE (but drive still works)
I installed it into my Son’s PC, as he is still on windows 10 and have never bothered installing CSE. He also has an existing MX500 500GB of his own. Installed CSE and low and behold BOTH my drive and his drive showing up with a Firmware error — but both drives are working.
Now, the drives are working, SMART stats look ok, but obviously cannot use CSE to change provisioning on drives or to run smart tests (or indeed for any future firmware upgrades).
Anyone have the same issue.
-
- Sep 22, 2010
-
- 8,981
-
- 643
-
- 36,390
-
#2
-
- Apr 5, 2022
-
- 5
-
- 0
-
- 10
-
#3
Is it just the 500GB SSD that throws the error, or does the 1TB version do it as well?
Just the 2 500GB (on firmware MC3R023) — the 1TB MX500 appears ok (firmware MC3R033) — I am assuming the 500GBs are an older controller revision hence the firmware difference
-
- Sep 22, 2010
-
- 8,981
-
- 643
-
- 36,390
-
#4
https://www.crucial.com/support/ssd-support/mx500-support
Version M3CR033:
This firmware will update the MX500 SSD from version M3CR032 to M3CR033. If your SSD has version any version besides M3CR032, this firmware update is not applicable and not necessary. M3CR033 includes the following changes:
- Fixed SATA protocol error that causes start-up failure on certain data center RAID systems)
- Improved boot time after unexpected power loss
- Fixed Read DMA command abort after an interrupted Secure Erase
The M3CR033 firmware is only compatible with drives that shipped with M3CR032.The M3CR023 firmware is compatible with all drives shipped with firmware other than M3CR032.
Edit:
I downloaded the two updates and extracted the firmware payload files (1.bin).
The 023 firmware contains a reference to Silicon Motion’s SM2258AA controller whereas the 033 firmware refers to SM2259AA. They also differ in the NAND flash chips (512Gbit versus 2Tbit).
Offset(h) 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F
00000680 53 4D 32 32 35 38 41 41 20 43 49 44 50 41 47 45 SM2258AA CIDPAGE
00000690 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 """"""""""""""""
000006A0 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 """"""""""""""""
000006B0 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 """"""""""""""""
000006C0 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 """"""""""""""""
000006D0 4D 69 63 72 6F 6E 2C 35 31 32 47 62 69 74 2C 4D Micron,512Gbit,M
000006E0 54 32 39 46 35 31 32 47 30 38 45 45 48 41 46 28 T29F512G08EEHAF(
000006F0 42 31 36 41 29 00 00 00 00 00 00 00 00 00 00 00 B16A)...........
Offset(h) 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F
00000680 53 4D 32 32 35 39 41 41 20 43 49 44 50 41 47 45 SM2259AA CIDPAGE
00000690 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 """"""""""""""""
000006A0 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 """"""""""""""""
000006B0 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 """"""""""""""""
000006C0 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 """"""""""""""""
000006D0 4D 69 63 72 6F 6E 2C 32 54 62 69 74 2C 4D 54 32 Micron,2Tbit,MT2
000006E0 39 46 32 54 30 38 45 4D 48 42 46 28 42 32 37 41 9F2T08EMHBF(B27A
000006F0 5F 45 53 35 29 28 53 4D 32 32 35 39 41 42 29 00 _ES5)(SM2259AB).
-
- Apr 5, 2022
-
- 5
-
- 0
-
- 10
-
#5
Was just wondering if this was a common problem, or specific to the 2 drives that happen to be in my house!
-
- Sep 22, 2010
-
- 8,981
-
- 643
-
- 36,390
-
#6
-
- Apr 5, 2022
-
- 5
-
- 0
-
- 10
-
#7
RMA’d one of the drives, replacement delivered today, and all functions in storage exec seem to work. new drive has different firmware level (M3CR043 ) which from the firmware download page implies another change in controller.
Definitely feels like a poor firmware upgrade that then crapped out Storage Exec…
Off to backup the other drive and RMA it next …
-
- Apr 5, 2022
-
- 5
-
- 0
-
- 10
-
#8
-
#9
-
#10
Disk is working perfectly fine in windows, but in Storage Executive, it’s not. It appears, disappears, Details opr smart reports lead to errors, etc.
The interresting thing is I noticed something: WHEN the disk is busy, copying files for example, then the problem disappear and storage executive perfectly works and make reports of my disk.
But when my disk is not busy, THEN? storage executive can’t do anything with it.
It’s like the disk was sleeping, so Storage Executive cannot communicate with it…
The problem, if this is correct, is I have no idea how we can fix the issue, even when Crucial will have a firmware relase for this… Firmware install will fail on tesring drive, and I’m not sure at all it’s a good idea to have the disk busy while its firmware is being updated (I don’t even know if this is do-able…)
My current firmware: MC3R043
-
#11
Similar threads
- Advertising
- Cookies Policies
- Privacy
- Term & Conditions
Crucial CT480BX500SSD1, работал в ноуте. Появились жалобы на фризы и зависания в работе.
SMART вроде как подозрений не вызывает,
а на графике чтения — два длительных провала практически до нуля. При этом данные всё-таки вычитываются, хотя и с околонулевой скоростью.
Утилита Crucial Storage Executive не позволяет выполнить Sanitize Drive, ссылаясь на ошибку микропрограммы для данного диска.
Штатным образом сделал trim и график чтения стал более-менее, но график записи не претерпел изменений.
Можно ли что-нибудь сделать с этим диском кроме как выбросить? Может быть «выключить» проблемную часть флэша или (как с хардами) оставить какую часть диска неразмеченной (хотя логика здесь совершенно другая)?
Здравствуйте, решил подготовиться к выходу стаклера2 и купил ссд crucial mx500 на 500гб. При покупке меня смутила стана производства т.к везде пишут Мексику, а у меня Малайзия.
И родная программа, которую я скачал с официального сайта, криво работает с этим ссд. Постоянно выдает «ошибку»- Команда прервана диском.
А еще диск пропадает из программы через какое-то время.
Смарт через кристалл диск читается нормально. Но один раз мне удалось прочитать смарт через родную программу.
Программа работала нормально в безопасном режиме до момента пока не включал моментум кэш, тогда появлялась ошибка.
Системки- fx8350, мать ga-970a-ds3p, в системе всего 3 диска — 2 ссд ( один системный, другой этот) и один хард. Проблема наблюдалась и на ноутбуке, а вот на старом компьютере с феномом 945 и какой-то материной на ам3 программа работала нормально. Везде вин 10 максимум различия в версиях сборки, на старом пк где-то 1903 ( точно не помню, возможно выше, но не ниже), на остальных пк все версии последние.
Собственно вопрос — стоит ли беспокоиться за ссд или забить?