Solved
Posted:
2021-06-29
08:01 AM
This was originally posted on APC forums on 3/24/2012
Hi,
Our new APC Back UPS Pro 1500 (4 days old) has started to show the F02 error every time it is switched on. Looking through the forums this is not an isolated problem and it appears that there is a problem with this range.
We’ve tried the «brain dead» technqiue to clear the memory as noted elsewhere on the forum several times but now the unit won’t switch on at all — just F02 and loud beeping. So after much cable re-arrangement and angst over the last few hours, the old set up and surge protection is back in place :o( — not happy as you can imagine. We did a lot of research on various UPS units and settled on APC as the best supplier — but unfortunately we missed the dreaded F02 issue.
We purchased the unit from a UK supplier but ideally we’d like APC to sort this out directly. How do we progress sorting this out please?
Thanks
Dave
Link copied. Please paste this link to share this article on your social media post.
-
All forum topics -
Previous Topic -
Next Topic
BillP
Administrator
Posted:
2021-06-29
08:01 AM
Posted:
2021-06-29
08:01 AM
This reply was originally posted by Allan on APC forums on 4/17/2012
you can try turning on the equipment, without the battery, wait 2-3 minutres, turn off and then reconnect the battery and see if the problem persist, the lcd equipment, most of the time, i have fixed them using that troubleshooting process
- back ups
Link copied. Please paste this link to share this article on your social media post.
Replies 2
BillP
Administrator
Posted:
2021-06-29
08:01 AM
Posted:
2021-06-29
08:01 AM
This reply was originally posted by Chris on APC forums on 4/3/2012
We would recommend you work with tech support for you region. They can walk you through any additional troubleshooting steps(if necessary) and will RMA a new back up(if necessary)
Link copied. Please paste this link to share this article on your social media post.
BillP
Administrator
Posted:
2021-06-29
08:01 AM
Posted:
2021-06-29
08:01 AM
This reply was originally posted by Allan on APC forums on 4/17/2012
you can try turning on the equipment, without the battery, wait 2-3 minutres, turn off and then reconnect the battery and see if the problem persist, the lcd equipment, most of the time, i have fixed them using that troubleshooting process
- back ups
Link copied. Please paste this link to share this article on your social media post.
Установка и эксплуатация Back-UPS BR1200G-RS/BR1500G-RS
6
Предупреждения и сбои системы
Звуковые предупреждения
Предупреждающие значки
Сбои в системе
Четыре звуковых сигнала каждые
30 секунд
Устройство Back-UPS работает от батареи. Необходимо сохранить все рабочие данные.
Непрерывный звуковой сигнал
Низкий уровень заряда батареи, устройства могут работать от батареи лишь короткое
время. Незамедлительно сохраните все данные, закройте все открытые приложения и
завершите работу операционной системы.
Непрерывный тональный сигнал
Выходы резервного питания батареи перегружены.
Минутные сигналы каждые 5
часов
Батарея не может автоматически выполнить диагностическую проверку и должна быть
заменена.
Если загорелся значок…
Возможна следующая проблема
Устройство Back-UPS работает от электросети с перегрузкой. Отключите одно из устройств,
подключенных к устройству Back-UPS. Если значок перегрузки перестает мигать, устройство
Back-UPS будет продолжать работу в обычном режиме без перегрузки.
Устройство Back-UPS работает от батареи с перегрузкой. Отключите одно из устройств,
подключенных к устройству Back-UPS. Если значок перегрузки перестает мигать, устройство
Back-UPS будет продолжать работу в обычном режиме без перегрузки.
Устройство Back-UPS работает от электросети, но батарея работает неправильно.
Обратитесь службу поддержки клиентов APC для заказа сменной батареи.
Устройство Back-UPS работает от батареи, зарядка которой заканчивается. Завершите работу
подключенного оборудования, чтобы не допустить потери несохраненных данных. Подключите
Back-UPS к электросети для зарядки батареи (когда это будет возможно).
F01
Перегрузка при работе от
батареи
Выключите устройство Back-UPS. Отключите
неиспользуемое оборудование от выходов
резервного питания и снова включите Back-UPS.
F02
Короткое замыкание выхода
при работе от батареи
Выключите устройство Back-UPS. Отключите
неиспользуемое оборудование от выходов
резервного питания и снова включите Back-UPS.
F03
Перегрузка Xcap при работе от
батареи
Сбои с кодами F03-F09 не могут быть устранены
пользователем. Обратитесь в службу технической
поддержки APC.
F04
Замыкание клемм
F05
Сбой зарядки
F06
Сварка реле
F07
Температура
F08
Неисправность вентилятора
F09
Внутренняя ошибка
bu
08
8a
Наш адрес: г. Москва, ул. Полярная, д. 31, стр. 1. Телефон: +7 495 649 16 77 (Skype, ICQ). Режим работы: понедельник — пятница с 9:00 до 18:00; суббота и воскресенье — выходной. Доставка по России, Белоруссии, Украине, Казахстану: Москва, Подольск, Сергиев Посад, Истра, Рязань, Курск, Липецк, Тула, Иваново, Воронеж, Ярославль, Тверь, Смоленск, Калуга, Белгород, Орел,
Тамбов, Кострома, Брянск, Красноярск, Норильск, Кемерово, Новокузнецк, Новосибирск, Омск, Барнаул, Иркутск, Братск, Бийск, Улан-Удэ, Томск, Абакан, Чита, Горно-Алтайск, Кызыл, Санкт-Петербург,
СПб, Выборг, Вологда, Череповец, Мурманск, Сыктывкар, Ухта, Архангельск, Северодвинск, Великий Новгород, Петрозаводск, Гомель, Гродно, Витебск, Могилев, Брест, Минск, Алма-Ата, Астана,
Ереван, Киев, Днепропетровск, Львов, Ташкент, Могилев, Псков, Калининград, Нарьян-Мар, Уфа, Стерлитамак, Самара, Тольятти, Сызрань, Нижний Новгород, Арзамас, Саратов, Энгельс, Пермь,
Ижевск, Казань, Набережные Челны, Бугульма, Пенза, Оренбург, Орск, Чебоксары, Новочебоксарск, Ульяновск, Киров, Йошкар-Ола, Саранск, Екатеринбург, Верхняя Пышма, Серов, Челябинск,
Магнитогорск, Снежинск, Тюмень, Курган, Нижневартовск, Сургут, Надым, Ростов-на-Дону, Волгодонск, Таганрог, Волгоград, Волжский, Краснодар, Армавир, Астрахань, Майкоп, Владивосток,
Уссурийск, Хабаровск, Комсомольск-на-Амуре, Советская Гавань, Южно-Сахалинск, Благовещенск, Петропавловск-Камчатский, Мирный, Ставрополь, Минеральные Воды, Махачкала, Нальчик, Алушта, Армянск, Джанкой, Евпатория, Керчь, Севастополь, Симферополь, Судак, Крым, Феодосия, Ялта. Сайт отвечает на вопросы: Как отремонтировать, настроить, установить оборудование? Где скачать документацию (инструкцию, мануал)? Где посмотреть партномер? Где купить запчасти (запасные
части, зип), комплектующие, аксессуары и термоэтикетка, чековая лента для весов, термопринтеров штрих-кода, чековых принтеров? Обслуживание весов, кассовых аппаратов, термопринтеров,
терминалов сбора данных, сканеров штрих-кода: каким образом возможно своими силами? Вас интересует наличие, цена, купить запчасти за наличный и безналичный расчет? — сделайте запрос
нашим менеджерам. Официальный сайт компании Zipstore.ru.
Разделы форума
Задать вопрос
Поиск
Регистрация
Личные данные
Авторизация
Раздел: Техническая поддержка — ИБП
Автор | Тема: APC Back-UPS Pro 900 — ошибки F02 и F06 |
||
Mihail321 Участник Сообщений: 13 На форуме с 18/03/15 |
2015-03-18 13:01:21 Добрый день. Есть 2 бесперебойника |
||
Chevyuser Участник Сообщений: 14098 На форуме с 24/02/10 |
|
||
Mihail321 Участник Сообщений: 13 На форуме с 18/03/15 |
|
||
Chevyuser Участник Сообщений: 14098 На форуме с 24/02/10 |
|
||
Chevyuser Участник Сообщений: 14098 На форуме с 24/02/10 |
|
||
Mihail321 Участник Сообщений: 13 На форуме с 18/03/15 |
|
||
Mihail321 Участник Сообщений: 13 На форуме с 18/03/15 |
|
||
Chevyuser Участник Сообщений: 14098 На форуме с 24/02/10 |
|
||
Chevyuser Участник Сообщений: 14098 На форуме с 24/02/10 |
|
||
Chevyuser Участник Сообщений: 14098 На форуме с 24/02/10 |
|
||
Mihail321 Участник Сообщений: 13 На форуме с 18/03/15 |
|
||
Mihail321 Участник Сообщений: 13 На форуме с 18/03/15 |
|
||
Mihail321 Участник Сообщений: 13 На форуме с 18/03/15 |
|
||
Mihail321 Участник Сообщений: 13 На форуме с 18/03/15 |
|
||
Mihail321 Участник Сообщений: 13 На форуме с 18/03/15 |
|
||
Mihail321 Участник Сообщений: 13 На форуме с 18/03/15 |
|
||
Basset Участник Сообщений: 61 На форуме с 12/05/11 |
|
||
Chevyuser Участник Сообщений: 14098 На форуме с 24/02/10 |
|
||
Mihail321 Участник Сообщений: 13 На форуме с 18/03/15 |
|
||
Mihail321 Участник Сообщений: 13 На форуме с 18/03/15 |
|
||
Chevyuser Участник Сообщений: 14098 На форуме с 24/02/10 |
|
||
Basset Участник Сообщений: 61 На форуме с 12/05/11 |
|
||
Basset Участник Сообщений: 61 На форуме с 12/05/11 |
|
||
Mihail321 Участник Сообщений: 13 На форуме с 18/03/15 |
|
||
Только зарегистрированные пользователи могут оставлять сообщения. Войдите под своим логином и паролем или Зарегистрируйтесь. |
Разделы форума
Задать вопрос
Поиск
Регистрация
Личные данные
Авторизация
What you find on this page:
No one likes seeing an error code on their APC, but this happens occasionally. So if you see the error code f02 on APC, learning what it means and how to resolve the issue are the best way to save yourself the headache if this happens again, and it probably will happen again at some point.
It can be incredibly frustrating when you use a device with an APC UPS (uninterruptible power supply) that isn’t working. There are several APC error codes, and APC f02 and APC f04 errors are the two most common, but we’ll focus on the error code f02 this time since many people experience this error.
We’ve compiled a guide to help you understand what the f02 error code on APC means and what you can do about it.
What Does f02 Mean on APC?
When you see the f02 error code on APC, the technical meaning is that the on-battery output is short. But what does this mean? Essentially, the battery is in the unit, but it’s not connecting to the attached device. You’re probably thinking you can solve this by removing and replacing the battery, but there are steps to take before you try that.
Fix APC f02 Error: Solutions
Now that you know what the f02 error code means, you can get to the root of the problem and resolve the error. Luckily, solving the f02 error code isn’t too challenging, as long as you know what you need to do. Here are the best solutions when APC shows this error code.
1. Just Power Off Your APC
As with most technology, the first thing you should do is power off your APC. When you power it off, it gives the device time to shut down and take a break. Sometimes, when you power it back on, the error code will likely be gone, and it will work like normal.
Unfortunately, not all situations will be resolved by simply turning the APC off and the back on. For example, if you power off the APC and turn it back on only to see the f02 error code, there are other steps you can take.
2. Remove the Power Cord From the Sector, and Keep the Battery
Once you’ve powered the APC back on and are still receiving the error code, you should remove the power cord from the sector. When you do this, be sure to keep the battery in place. Some people will tell you to remove the battery, but when you’re restarting the device, you don’t need to remove the battery. That’s a step you’ll take when resetting the APC, not restarting.
3. Press Constantly Power Button Until You Hear the Second Beep Signal
After you remove the power cord, you’ll want to press down on the power button constantly. You don’t want to press down and remove your finger and then press down again. You’ll want to keep your finger on the power button consistently.
Pressing the power button until you hear a beep triggers the APC to restart. You’ll keep pressing down on the power button until you hear the second beeping signal.
4. Let the APC Restart; It Will Mark the f02 Error Again
Once you hear the second beeping signal, you can remove your finger and let the APC restart. It shouldn’t take long for the APC to restart, and you’ll likely still see the f02 error code again. Don’t panic if you see this. You’re supposed to still see the f02 error code at this point.
5. Plug the Power Cord
After this step, you’ll want to replace the power cord with the appropriate outlets. It might seem obvious to mention this step, but we want to give as clear instructions as possible. You can’t restart the APC without plugging the power cord back in, and you won’t be able to see if the APC error f02 is gone without this step.
When plugging the power cord back in, make sure you choose an outlet that is a reliable power source for the device. Something else to keep in mind is that you’ll want to plug the power cord back in while the device is powered off. Again, this is the safest way for you and your device’s health.
6. Restart the APC
With the power cord plugged back into the APC and power outlet, you’re ready to restart your APC. You’ll do this by pressing the power button and letting the device reboot. If there aren’t any serious issues with your APC, this should solve your f02 error code situation.
After you’ve restarted your APC, if you’re still seeing the f02 error, you might need to consider resetting the APC backup.
How Do I Reset My APC?
Sometimes unplugging the power cord and restarting the APC won’t work. If you try the above steps and you’re still seeing the APC on-battery output short error code, you’ll want to try resetting the APC. Resetting your APC and restarting them is a little bit different. Here’s how you can reset your APC UPS:
- Disconnect all loads attached to the APC
- Unplug your APC UPS from the wall outlet
- Disconnect the APC’s internal battery
- Press and hold down the “on” button for about five seconds before letting go
- Reconnect the internal battery
- Plug the APC UPS into a high-quality power source
- Turn the APC on
The above steps should successfully reset your APC. Resetting the device can usually solve many of the error code issues you’ll experience with the APC UPS. However, if restarting and then resetting your device doesn’t work, you might have a more severe problem with the hardware. The best thing you can do is contact APC directly for assistance.
Why Is My APC Backup Product Beeping?
If your APC backup product is beeping, it only means one thing. The product beeping indicates that the battery is running low and will soon need to power off. If you’re wondering, “why is my APC battery backup blinking?” Blinking is another indicator that the battery is running low and will turn off soon.
When your APC backup is beeping, you’ll want to replace the battery or charge it as soon as possible so that it doesn’t shut off on you when you’re in the middle of something.
Conclusion
There are a lot of APC UPS error codes to learn about, but an APC UPS f02 error code isn’t a cause for too much concern. The f02 error on an APC just means that the battery is in the device, but it’s not connecting.
Now you might be asking yourself, “How do I fix the APC f04 error code?” As long as you follow the steps above, you should be able to resolve the APC f02 warning in no time.
FAQs
Is my APC UPS under warranty?
When you purchase your APC UPS, you have the option to pay for a warranty. The warranty will run from the date of purchase for a specified period. Of course, how long your warranty lasts depends, but if you’re unsure, you look at the serial number of your product or get in touch with APC directly to find out if you still have a warranty on the device.
Can I replace the APC battery while running?
Yes! You can change the APC battery while it’s running if you need to. The battery is hot-swappable, so you don’t have to power off your device to replace the battery. Being able to replace the battery while it’s running is very handy when you’re in the middle of work and don’t want to pause your day to replace the battery.
How much does APC UPS cost?
The cost of an APC UPS will vary. It depends on the specific product you purchase, the size, where you are buying it from, and which manufacturing year you choose. The newer models will almost always cost more than older ones, but you can expect to pay anywhere from $50 to nearly $1,000.
How do I check my APC UPS warranty?
If you kept the receipt you received when you purchased your APC UPS, you should be able to see the warranty and how long it is on that. If you don’t, you can get in touch with APC directly for them to look up whether you have a warranty still on your device or look at the serial number.
Specific numbers will indicate what year and week it was made. This information can help you determine if you still have a warranty. For example, if you see the numbers 20 and then 16, that indicates APC made it in 2020 on the 16th week of the year.
Установка и эксплуатация Back-UPS BR1200G-RS/BR1500G-RS
6
Предупреждения и сбои системы
Звуковые предупреждения
Предупреждающие значки
Сбои в системе
Четыре звуковых сигнала каждые
30 секунд
Устройство Back-UPS работает от батареи. Необходимо сохранить все рабочие данные.
Непрерывный звуковой сигнал
Низкий уровень заряда батареи, устройства могут работать от батареи лишь короткое
время. Незамедлительно сохраните все данные, закройте все открытые приложения и
завершите работу операционной системы.
Непрерывный тональный сигнал
Выходы резервного питания батареи перегружены.
Минутные сигналы каждые 5
часов
Батарея не может автоматически выполнить диагностическую проверку и должна быть
заменена.
Если загорелся значок…
Возможна следующая проблема
Устройство Back-UPS работает от электросети с перегрузкой. Отключите одно из устройств,
подключенных к устройству Back-UPS. Если значок перегрузки перестает мигать, устройство
Back-UPS будет продолжать работу в обычном режиме без перегрузки.
Устройство Back-UPS работает от батареи с перегрузкой. Отключите одно из устройств,
подключенных к устройству Back-UPS. Если значок перегрузки перестает мигать, устройство
Back-UPS будет продолжать работу в обычном режиме без перегрузки.
Устройство Back-UPS работает от электросети, но батарея работает неправильно.
Обратитесь службу поддержки клиентов APC для заказа сменной батареи.
Устройство Back-UPS работает от батареи, зарядка которой заканчивается. Завершите работу
подключенного оборудования, чтобы не допустить потери несохраненных данных. Подключите
Back-UPS к электросети для зарядки батареи (когда это будет возможно).
F01
Перегрузка при работе от
батареи
Выключите устройство Back-UPS. Отключите
неиспользуемое оборудование от выходов
резервного питания и снова включите Back-UPS.
F02
Короткое замыкание выхода
при работе от батареи
Выключите устройство Back-UPS. Отключите
неиспользуемое оборудование от выходов
резервного питания и снова включите Back-UPS.
F03
Перегрузка Xcap при работе от
батареи
Сбои с кодами F03-F09 не могут быть устранены
пользователем. Обратитесь в службу технической
поддержки APC.
F04
Замыкание клемм
F05
Сбой зарядки
F06
Сварка реле
F07
Температура
F08
Неисправность вентилятора
F09
Внутренняя ошибка
bu
08
8a
Наш адрес: г. Москва, ул. Полярная, д. 31, стр. 1. Телефон: +7 495 649 16 77 (Skype, ICQ). Режим работы: понедельник — пятница с 9:00 до 18:00; суббота и воскресенье — выходной. Доставка по России, Белоруссии, Украине, Казахстану: Москва, Подольск, Сергиев Посад, Истра, Рязань, Курск, Липецк, Тула, Иваново, Воронеж, Ярославль, Тверь, Смоленск, Калуга, Белгород, Орел,
Тамбов, Кострома, Брянск, Красноярск, Норильск, Кемерово, Новокузнецк, Новосибирск, Омск, Барнаул, Иркутск, Братск, Бийск, Улан-Удэ, Томск, Абакан, Чита, Горно-Алтайск, Кызыл, Санкт-Петербург,
СПб, Выборг, Вологда, Череповец, Мурманск, Сыктывкар, Ухта, Архангельск, Северодвинск, Великий Новгород, Петрозаводск, Гомель, Гродно, Витебск, Могилев, Брест, Минск, Алма-Ата, Астана,
Ереван, Киев, Днепропетровск, Львов, Ташкент, Могилев, Псков, Калининград, Нарьян-Мар, Уфа, Стерлитамак, Самара, Тольятти, Сызрань, Нижний Новгород, Арзамас, Саратов, Энгельс, Пермь,
Ижевск, Казань, Набережные Челны, Бугульма, Пенза, Оренбург, Орск, Чебоксары, Новочебоксарск, Ульяновск, Киров, Йошкар-Ола, Саранск, Екатеринбург, Верхняя Пышма, Серов, Челябинск,
Магнитогорск, Снежинск, Тюмень, Курган, Нижневартовск, Сургут, Надым, Ростов-на-Дону, Волгодонск, Таганрог, Волгоград, Волжский, Краснодар, Армавир, Астрахань, Майкоп, Владивосток,
Уссурийск, Хабаровск, Комсомольск-на-Амуре, Советская Гавань, Южно-Сахалинск, Благовещенск, Петропавловск-Камчатский, Мирный, Ставрополь, Минеральные Воды, Махачкала, Нальчик, Алушта, Армянск, Джанкой, Евпатория, Керчь, Севастополь, Симферополь, Судак, Крым, Феодосия, Ялта. Сайт отвечает на вопросы: Как отремонтировать, настроить, установить оборудование? Где скачать документацию (инструкцию, мануал)? Где посмотреть партномер? Где купить запчасти (запасные
части, зип), комплектующие, аксессуары и термоэтикетка, чековая лента для весов, термопринтеров штрих-кода, чековых принтеров? Обслуживание весов, кассовых аппаратов, термопринтеров,
терминалов сбора данных, сканеров штрих-кода: каким образом возможно своими силами? Вас интересует наличие, цена, купить запчасти за наличный и безналичный расчет? — сделайте запрос
нашим менеджерам. Официальный сайт компании Zipstore.ru.
Topic: APC BR1500GI F02 Output Short (Read 4826 times)
0 Members and 1 Guest are viewing this topic.
I have an APC BackUPS Pro BR1500GI which I bought new in 2013. It has been sitting in the cupboard faulty until now.
The problem arose after a power spike The AC voltage went to 315V for a couple seconds (I have no idea why to this date). The UPS went to battery, then when it went to switch back to AC I had the error code F02 displayed with a constant screech for help that cannot be muted. There was no funny smells or magic smoke at the time of the fault.
From the sound the UPS is making it appears to be in terrible pain!!
This screeching error code happens constantly. With batteries and without. With or without devices connected to the outputs. The unit cannot be powered off or silenced apart from unplugging the AC.
I of course, tried new batteries, which did not help so I bough a second-hand unit (which I have been using since) and put the batteries in that one which is fine now 2 years later.
All the manual says regarding F02 is:
F02 On-Battery Output Short
Turn the Back-UPS off. Disconnect non-essential
equipment from the Battery Backup outlets and the turn
Back-UPS on.
This advice does not help at all.
I got onto APC three times in 2019 and they basically said «naf off» to me when I asked for customer support. I even said I was prepared to send it to them for service and they said I would have to post it to the USA and the cost is $950 plus shipping and they won’t guarantee the repair. I definitely will not be buying new products from APC ever again!
Searching the F02 fault online shows up dozens of other people with the same F02 fault code, some with other models, some saying their UPS were brand new!!! So it is a common issue! Especially with the BR1500 models which are mentioned a few times
So now I have a little more electronics knowledge I have been brave enough to take it apart. I found two faults.
The first was C83 100µF 25V. It was bulging and had an ESR of 124Ω and capacitance of 1.6µF. I have replaced this with a new capacitor.
The second fault was another capacitor that had one leg never soldered to the pad from new! It was just flapping in the wind! I tested it’s value and ESR and it is good so I soldered it in place correctly. (see photos).
I tested the ESR of every other Electrolytic cap on the board and they are good.
I have tested the MOSFET transistors on the big heat-sinks for shorts. They appear to be fine!
So I am hoping someone here may be more knowledgeable than I am regarding this issue and might be able to help me find the fault.
« Last Edit: August 19, 2022, 06:32:59 pm by paul_g_787 »
Logged
Something must be sensing the current draw. Look for low value, high power resistances. Alternatively, the unit may be sensing the current via a winding in a transformer.
I would think that the battery charging circuit must have some current sensing circuitry.
Logged
Something must be sensing the current draw. Look for low value, high power resistances. Alternatively, the unit may be sensing the current via a winding in a transformer.
I would think that the battery charging circuit must have some current sensing circuitry.
To the best of my knowledge APC use current transformers to measure AC current, in this case on the output, and in some cases on the AC input feed as well,
It is possible that the circuit that conditions the current transformer output has been damaged — either the load current is being reported as too high, or maybe reported as being zero when the the UPS knows full well that it isn’t.
My advice would be to try and find a schematic*, and try to trace how power gets from the line to the sockets, keeping your eye open for a transformer marked «CT» (=current transformer) rather than «T» (=input power transformer or inverter output transformer)
If the BR1500 is anything like my SU1400, then look for any transformer marked «CT» rather than «T». For example on the SU1400 there are CT1, CT2.
Then look at what each current transformer feeds — look for clamping diodes, burden resistors across the output, then look at where the signal goes afterwards.
On the SU1400 CT2 senses the output current (it’s the last component before the «HOT-OUT» connector, and the transformer output goes through two op-amps before arriving at an ADC.
If you have a schematic, you have a fighting chance of at least locating the fault. Without one (IMHO), you might as well give up…
/JK
* Use the elektrotanya.com search, search for APC then manually look through the results.
Logged
I had the same output short issue with this ups and have successfully fixed by the replacing the 4 mosfets at the output. This reply is for all the future visitors looking to fix the issue. The Apc back-ups pro 1000 uses four Irf740 mosfets, whereas the 1500va model uses fdp22N50N. Replace all four mosfets .
Logged
I had the same output short issue with this ups and have successfully fixed by the replacing the 4 mosfets at the output. This reply is for all the future visitors looking to fix the issue. The Apc back-ups pro 1000 uses four Irf740 mosfets, whereas the 1500va model uses fdp22N50N. Replace all four mosfets .
Hi Thanks for that info! I still have the faulty BR1500GI UPS. I will dig it out and have a look at the four mosfets.
Don’t suppose you have a photo of the one you repaired to help me locate these four mosfets?
I remember I tested all the large transistors for shorts and couldn’t find an issue before. Maybe I missed one or didn’t test properly.
Any tips how to test them? would you test a mosfet in the same way as a BJT?
I have had a look and there are two different IRF740 mosfets I can get. The IRF740PBF or the IRF740APBF.
Hopefully it is clearly labelled on the package. I will have a look and see.
Logged
I had the same output short issue with this ups and have successfully fixed by the replacing the 4 mosfets at the output. This reply is for all the future visitors looking to fix the issue. The Apc back-ups pro 1000 uses four Irf740 mosfets, whereas the 1500va model uses fdp22N50N. Replace all four mosfets .
Hi Thanks for that info! I still have the faulty BR1500GI UPS. I will dig it out and have a look at the four mosfets.
Don’t suppose you have a photo of the one you repaired to help me locate these four mosfets?
I remember I tested all the large transistors for shorts and couldn’t find an issue before. Maybe I missed one or didn’t test properly.
Any tips how to test them? would you test a mosfet in the same way as a BJT?
I have had a look and there are two different IRF740 mosfets I can get. The IRF740PBF or the IRF740APBF.
Hopefully it is clearly labelled on the package. I will have a look and see.
Opening up my 1500 va UPS and showing you the mosfets at the out output. You can check all three legs of the four mosfets with multimeter without removing them. Mine 1000va ups had two mosfets shorted but i replaced all four.
Here it is :
[attachimg=1]
Logged
This is the inside of my BR1500GI, there are a whole bunch of MOSFETs by the looks of it from the picture.
I do remember I did test between the pins on each one of these for shorts originally but never found a problem before.
I will try them again. Not sure which ones are the output stage MOSFETs though.
« Last Edit: August 21, 2022, 05:07:56 pm by paul_g_787 »
Logged
The ones with two legs are diodes and the others with 3 legs are all MOSFETS. Have you checked the output relays for any short?
Logged
The ones with two legs are diodes and the others with 3 legs are all MOSFETS. Have you checked the output relays for any short?
OK thanks for pointing that out, I have tested all the diodes and they are not shorted.
I was measuring a possible short on the 4 MOSFETs but could not get a definite reading So I have de-soldered them and will test them out of circuit and will post back later.
There are 4 MOSFETS, they are all IRF2805. I believe this is the datasheet here:
https://www.infineon.com/dgdl/irf2805pbf.pdf?fileId=5546d462533600a4015355de928518eb
I also tested all the relay switches using my bench power supply. I set the power supply to 24V 30mA and used my multi-meter probes plugged into the power supply to apply power to the relays. All 6 of the relays switched just fine when power was applied.
The 5 black Relays are a 793-P-1C-S and this is the datasheet.
https://eu.mouser.com/datasheet/2/378/793p-347351.pdf
The White relay I cannot read the part no as it is worn out but the rated voltage is 24V also.
Logged
The ones with two legs are diodes and the others with 3 legs are all MOSFETS. Have you checked the output relays for any short?
I also tested all the relay switches using my bench power supply. I set the power supply to 24V 30mA and used my multi-meter probes plugged into the power supply to apply power to the relays. All 6 of the relays switched just fine when power was applied.
Did you tested the NO NC points of the relays with COMMON point? Most of the times the relays switches perfectly fine but its NO NC points are Burned . To test the relays you should first test all of them with the multimeter on continuity mode. The COMMON and NC point should give beep. When you apply power to the relay , COMMON and NO points gets connected and should not give a beep on COMMON and NC and vice versa.
« Last Edit: August 19, 2022, 12:48:51 pm by Dinesh6252 »
Logged
I also tested all the relay switches using my bench power supply. I set the power supply to 24V 30mA and used my multi-meter probes plugged into the power supply to apply power to the relays. All 6 of the relays switched just fine when power was applied.
Did you tested the NO NC points of the relays with COMMON point? Most of the times the relays switches perfectly fine but its NO NC points are Burned . To test the relays you should first test all of them with the multimeter on continuity mode. The COMMON and NC point should give beep. When you apply power to the relay , COMMON and NO points gets connected and should not give a beep on COMMON and NC and vice versa.
[/quote]
I tested the common to NC connections with no power and they all have continuity.
But I did not test between common and NO. I will definitely do that when I get home! Good shout.
Logged
I also tested all the relay switches using my bench power supply. I set the power supply to 24V 30mA and used my multi-meter probes plugged into the power supply to apply power to the relays. All 6 of the relays switched just fine when power was applied.
Did you tested the NO NC points of the relays with COMMON point? Most of the times the relays switches perfectly fine but its NO NC points are Burned . To test the relays you should first test all of them with the multimeter on continuity mode. The COMMON and NC point should give beep. When you apply power to the relay , COMMON and NO points gets connected and should not give a beep on COMMON and NC and vice versa.
I tested the common to NC connections with no power and they all have continuity.
But I did not test between common and NO. I will definitely do that when I get home! Good shout.
[/quote]
Alright I tested all the relays between the Common and NO pins and used my bench supply to turn the relays on and yes all of them switch and have continuity in the NO position.
The 5 black relays are all SPDT, the white relay is DPDT and I tested both poles and can confirm they are working.
Interestingly one of the black relays stays on for 5 seconds after switching it, probably a capacitor to hold it in the on position to stop it turning on and off too fast I reckon.
Logged
This is the first time I have properly delved into MOSFETs so please be patient with me on this one.
So I found this article very useful: https://www.homemade-circuits.com/how-to-check-mosfet-using-digital/
And I followed this procedure for testing the four IRF2805 MOSFETs which are N channel.
The pinout is Gate, Drain, Source when looking from the front of the TO-220 package.
How to Check N-Channel Mosfets
1) Set the DMM to the diode range.
2) Keep the mosfet on a dry wooden table on its metal tab, with the printed side facing you and leads pointed towards you.
3) With a screwdriver or meter probe, short the gate and drain pins of the mosfet. This will initially keep the internal capacitance of the device completely discharged.
4) Now Touch the meter black probe to source and the red probe to drain of the device.
5)You should see an «open» circuit indication on the meter.
6) Now keeping the black probe touched to the source, lift the red probe from drain and touch it to the gate of the mosfet momentarily, and bring it back to the drain of the mosfet.
7) This time the meter will show a short circuit (sorry, not short-circuit rather «continuity).
The results from the point 5 and 7 confirms that the mosfet is OK.
Repeat this procedure many times for proper confirmation.
For repeating the above procedure each time, you will need to reset the MOSFET by shorting the gate and the drain leads using meter probe as explained earlier.
The results are just as the article describes:
I first short Gate and Drain with a screwdriver.
Then using my meter in continuity / diode test mode, I measure from Drain to Source it reads OL (overload).
Then I momentarily move the red probe from Drain to Gate keeping the black probe on Source at all times.
Then move the red probe back to Drain and I get a continuity reading.
All four of the MOSFET switch in this fashion as expected and I have repeated the test 10 times for each MOSFET to confirm and wrote down the readings..
The average readings my meter give for each MOSFET is as follows:
MOSFET 1: 0.17
MOSFET 2: 0.28
MOSFET 3: 0.25
MOSFET 4: 0.37
I am wondering why such a difference in the readings? Does this perhaps indicate a fault?
IRD2805 Datasheet:
file:///home/paul/Documents/Electronics/Datasheets/Transistors/MOSFET/Infineon-IRF2805-DataSheet-v01_01-EN.pdf
« Last Edit: August 19, 2022, 06:34:38 pm by paul_g_787 »
Logged
I am wondering why such a difference in the readings? Does this perhaps indicate a fault?
Well that’s not exactly a very «scientific» method of testing, so the results will vary a bit depending on how much charge you put on the gate of the MOSFET. The voltage supplied by the multimeter might not even be enough to fully turn on the MOSFET. Also it’s normal to have some variance between components, no two MOSFETs of the same type are going to be perfectly identical.
The important thing is, that the MOSFETs are not shorted and appear to switch on/off normally, which this simple test has proven, so its safe to say these MOSFETs are not at fault.
Realistically, checking for short circuits actually would have been good enough, as power MOSFETs virtually always fail with a short circuit between two (or all 3) pins. If there is sufficient energy to blow the MOSFET open-circuit, there will be visual clues.
Logged
I am wondering why such a difference in the readings? Does this perhaps indicate a fault?
Well that’s not exactly a very «scientific» method of testing, so the results will vary a bit depending on how much charge you put on the gate of the MOSFET. The voltage supplied by the multimeter might not even be enough to fully turn on the MOSFET. Also it’s normal to have some variance between components, no two MOSFETs of the same type are going to be perfectly identical.
The important thing is, that the MOSFETs are not shorted and appear to switch on/off normally, which this simple test has proven, so its safe to say these MOSFETs are not at fault.
Realistically, checking for short circuits actually would have been good enough, as power MOSFETs virtually always fail with a short circuit between two (or all 3) pins. If there is sufficient energy to blow the MOSFET open-circuit, there will be visual clues.
OK that is good to know. This was what I was thinking too but as I said I haven’t had much experience with MOSFETS so was just making an educated guess. So at least these appear to be working OK which is good news.
Question is now what to check next for the F02 Output Short error? A previous post mentioned current transformers so I will have a look see if I can find anything like that next unless anyone has any other ideas.
Logged
Something must be sensing the current draw. Look for low value, high power resistances. Alternatively, the unit may be sensing the current via a winding in a transformer.
I would think that the battery charging circuit must have some current sensing circuitry.
To the best of my knowledge APC use current transformers to measure AC current, in this case on the output, and in some cases on the AC input feed as well,
It is possible that the circuit that conditions the current transformer output has been damaged — either the load current is being reported as too high, or maybe reported as being zero when the the UPS knows full well that it isn’t.My advice would be to try and find a schematic*, and try to trace how power gets from the line to the sockets, keeping your eye open for a transformer marked «CT» (=current transformer) rather than «T» (=input power transformer or inverter output transformer)
If the BR1500 is anything like my SU1400, then look for any transformer marked «CT» rather than «T». For example on the SU1400 there are CT1, CT2.
Then look at what each current transformer feeds — look for clamping diodes, burden resistors across the output, then look at where the signal goes afterwards.
On the SU1400 CT2 senses the output current (it’s the last component before the «HOT-OUT» connector, and the transformer output goes through two op-amps before arriving at an ADC.If you have a schematic, you have a fighting chance of at least locating the fault. Without one (IMHO), you might as well give up…
/JK
* Use the elektrotanya.com search, search for APC then manually look through the results.
OK so there are indeed two transformers here labelled CT10 and CT11 just as on your model. See the image attached, they are right in the middle of the image between the black relays.
So these are used to sense the current? One then I assume is used to sense the output current which is how the UPS knows the load. What is the other for?
Unfortunately I cannot find a schematic for the BR1500GI. ElektroTanya was where I first searched but despite looking manually as you suggested I still could not find one.
Logged
Curious that anyone would dream they could find a UPS schematic…
Logged
Установка и эксплуатация Back-UPS BR1200G-RS/BR1500G-RS
6
Предупреждения и сбои системы
Звуковые предупреждения
Предупреждающие значки
Сбои в системе
Четыре звуковых сигнала каждые
30 секунд
Устройство Back-UPS работает от батареи. Необходимо сохранить все рабочие данные.
Непрерывный звуковой сигнал
Низкий уровень заряда батареи, устройства могут работать от батареи лишь короткое
время. Незамедлительно сохраните все данные, закройте все открытые приложения и
завершите работу операционной системы.
Непрерывный тональный сигнал
Выходы резервного питания батареи перегружены.
Минутные сигналы каждые 5
часов
Батарея не может автоматически выполнить диагностическую проверку и должна быть
заменена.
Если загорелся значок…
Возможна следующая проблема
Устройство Back-UPS работает от электросети с перегрузкой. Отключите одно из устройств,
подключенных к устройству Back-UPS. Если значок перегрузки перестает мигать, устройство
Back-UPS будет продолжать работу в обычном режиме без перегрузки.
Устройство Back-UPS работает от батареи с перегрузкой. Отключите одно из устройств,
подключенных к устройству Back-UPS. Если значок перегрузки перестает мигать, устройство
Back-UPS будет продолжать работу в обычном режиме без перегрузки.
Устройство Back-UPS работает от электросети, но батарея работает неправильно.
Обратитесь службу поддержки клиентов APC для заказа сменной батареи.
Устройство Back-UPS работает от батареи, зарядка которой заканчивается. Завершите работу
подключенного оборудования, чтобы не допустить потери несохраненных данных. Подключите
Back-UPS к электросети для зарядки батареи (когда это будет возможно).
F01
Перегрузка при работе от
батареи
Выключите устройство Back-UPS. Отключите
неиспользуемое оборудование от выходов
резервного питания и снова включите Back-UPS.
F02
Короткое замыкание выхода
при работе от батареи
Выключите устройство Back-UPS. Отключите
неиспользуемое оборудование от выходов
резервного питания и снова включите Back-UPS.
F03
Перегрузка Xcap при работе от
батареи
Сбои с кодами F03-F09 не могут быть устранены
пользователем. Обратитесь в службу технической
поддержки APC.
F04
Замыкание клемм
F05
Сбой зарядки
F06
Сварка реле
F07
Температура
F08
Неисправность вентилятора
F09
Внутренняя ошибка
bu
08
8a