#1
All is now well!!!!! Turns out that the memory sticks were not properly seated. When I finally got them properly seated, everything is working perfectly. I always err on the side of using less force, but in this case, more force was the answer.
I have the following parts and am unable to boot the system.
Supermicro X11SSH-CTF-B LGA1151/ Intel C236/ DDR4/ SATA3&SAS3&USB3.0/ V&2GbE/ MicroATX Server Motherboard
Timetec Hynix IC 32GB KIT (2x16GB) DDR4 2666MHz PC4-21300 Unbuffered ECC 1.2V CL19 2Rx8 Dual Rank 288 Pin UDIMM Server Memory RAM Module Upgrade
Xeon E3-1230 v6
If I am reading everything properly, these parts should be compatible but when the system boots, I see the following on the monitor,
PEI — IPMI Initialization
then I hear 5 short beeps and one long beep that according to the users manual indicates a memory error
And the monitor reads
0X06 = mrcReadMPRErr
I have tried only one memory module and cleared the CMOS.
Is there an incompatibility that I am missing?
All Help Will Be Greatly Appreciated.
Thanks
Bob Ivey
Last edited:
Перейти к контенту
-
#1
Hi, this is my first post connected with new hardware.
I’m starting to build up a server.
I have such a devices:
MB: SuperMicro X11SSL-F
CPU: e3-1230v6
RAM: Samsung 4x16GB 2400 UDIMM ECC.
I had build up the PC, run it and I hear 5 short beeps and one long.
Then I entered to the IMPI and I see following Hardware list.
which is completely different, because Now I have v6 cpu and only one Ram on the board.
Here is stated bios 2.0c, but on the other site there is an 2.1a
On monitor I see something like that:
0x09 mrc data time centering 1d error
What should I do?
-
#2
- place one stick of ram in slot DIMMA1
- reset your ipmi back to factory default
- reboot the system
-
#3
did it,
now there is other issue
the system works only with 2 memory slots occupied — so only 32GB ram.
If I put 3.rd or 4th ram stick the system can not boot.
I get such error exactly:
Code:
0x09=mrcDataTimeCentering1DErr
I can only occupy the 2 first slots from the top (black and blue)
-
#5
Are all four of the ram modules part#M391A2K43BB1-CRC ???
Test each stick (one at a time) in the first ram slot (if one of the
sticks fails to boot) you may have a bad stick of ram.
-
#6
Disable the jumpers of SMB to PCI Slots (JI2C1/JI2C2) — from 1-2 to 2-3 and all will be fine
DrKK
FreeNAS Generalissimo
-
#7
Disable the jumpers of SMB to PCI Slots (JI2C1/JI2C2) — from 1-2 to 2-3 and all will be fine
really. What does that do?
-
#8
This is due to hardware limitation as the result of SMBus address conflict between DIMMA1 and the PCIe devices
-
#9
This is due to hardware limitation as the result of SMBus address conflict between DIMMA1 and the PCIe devices
How do you arrive at that conclusion?
-
#10
my system (X11-SSM) had same problems with 4pcs of 16GB modules (beeps at startup, 0x09=mrcDataTimeCentering1DErr, etc). I got information from Supermicro support about hardware limitations for SSM/SSL/SSH mainboards. And after setting jumpers to disable SMBus — system can start normally, w/o beeps and with all 64GB.
Very easy to check, but i don’t know where is TS — yacenty
Last edited: May 13, 2018
-
#11
Interesting. I assume those DIMMs are not on the QVL?
-
#12
yes ) HPE with SK Hynix chips
-
#13
my system (X11-SSM) had same problems with 4pcs of 16GB modules (beeps at startup, 0x09=mrcDataTimeCentering1DErr, etc). I got information from Supermicro support about hardware limitations for SSM/SSL/SSH mainboards. And after setting jumpers to disable SMBus — system can start normally, w/o beeps and with all 64GB.
Very easy to check, but i don’t know where is TS — yacenty
RSA- I was having this exact issue whenever I tried putting in 4DIMMS… your post saved me a ton of wasted time and heartache!!! Thank you!!!!
-
#14
RSA- I was having this exact issue whenever I tried putting in 4DIMMS… your post saved me a ton of wasted time and heartache!!! Thank you!!!!
i’m really happy to help you
1 / 1 / 0 Регистрация: 10.10.2019 Сообщений: 9 |
|
1 |
|
18.03.2021, 16:20. Показов 11588. Ответов 11
Доброго времени суток. Есть сервер со следующей конфигурацией:
Проблема заключается в том,что при включении сервера на экране появляется логотип SuperMicro на белом фоне,внизу слева следуют надписи: Код PEI—IPMI Initialization... PEI—SB Initialization... (появляется на миллисекунду) PEI—Intel MRC Execution... (справа код 2F) После этого ничего не происходит. В чём может быть проблема?
__________________ 0 |
4448 / 2135 / 432 Регистрация: 09.09.2017 Сообщений: 7,742 |
|
18.03.2021, 16:38 |
2 |
I_FarEvil_I, Не поддерживает мат. плата регистровую (буферизированную) память. Для проца и мат. платы заявлена только поддержка ECC-памяти (с коррекцией ошибок). 0 |
1 / 1 / 0 Регистрация: 10.10.2019 Сообщений: 9 |
|
18.03.2021, 16:39 [ТС] |
3 |
ibarg, то есть нужно идти покупать UDIMM? 0 |
4448 / 2135 / 432 Регистрация: 09.09.2017 Сообщений: 7,742 |
|
18.03.2021, 16:41 |
4 |
покупать UDIMM? По ходу да. 0 |
1 / 1 / 0 Регистрация: 10.10.2019 Сообщений: 9 |
|
18.03.2021, 16:47 [ТС] |
5 |
Хорошо, спасибо за информацию. В ближайшее время куплю UDIMM память, если будет подобное-напишу. 0 |
1376 / 508 / 99 Регистрация: 11.03.2015 Сообщений: 1,735 |
|
19.03.2021, 13:18 |
6 |
I_FarEvil_I, 1 |
0 / 0 / 0 Регистрация: 15.06.2021 Сообщений: 3 |
|
15.06.2021, 09:36 |
7 |
В итоге, с какой именно запустилось? 0 |
1 / 1 / 0 Регистрация: 10.10.2019 Сообщений: 9 |
|
15.06.2021, 12:08 [ТС] |
8 |
dompro, UDIMM ECC DDR4, у меня — Samsung M391A4G43MB1-CTDQY 1 |
0 / 0 / 0 Регистрация: 15.06.2021 Сообщений: 3 |
|
24.06.2021, 12:35 |
9 |
Попробовал Kingston KSM32ES8/8ME , та же ошибка. Это на 3200 частоты, но подстраивается под 2666. Но похоже плате нужно жестко конкретно 2666? 0 |
1 / 1 / 0 Регистрация: 10.10.2019 Сообщений: 9 |
|
24.06.2021, 13:23 [ТС] |
10 |
плате нужно жестко конкретно 2666? Да. 0 |
0 / 0 / 0 Регистрация: 15.06.2021 Сообщений: 3 |
|
06.07.2021, 13:17 |
11 |
Какая-то хрень, опять ждал пока доедет другая плашка, купил Samsung [M391A1K43BB2-CTD] 8 ГБ, поставил и то же самое. Может дело не в памяти? Уже двадцать раз пожалел что эту материнку выбрал. 0 |
1376 / 508 / 99 Регистрация: 11.03.2015 Сообщений: 1,735 |
|
12.07.2021, 13:01 |
12 |
dompro, Error code 2F means memory initialization. It is generated thru the BIOS. You may have memory issue. Please check your memory DIMMs and motherboard’s DIMM sockets. Скачайте мануал от материнки с этой страницы: 0 |
IT_Exp Эксперт 87844 / 49110 / 22898 Регистрация: 17.06.2006 Сообщений: 92,604 |
12.07.2021, 13:01 |
12 |
I recently built a new server which I’ve been testing successfully without peripherals. I picked up a PERC H200 that I intend to flash to IT mode (but is currently in IR mode) that I intended to use for my HBA. Unfortunately, when I install the card, the system refuses to boot.
The relevant components of the system in question are:
-
Supermicro X11SSM-F (BIOS 2.0a)
-
Xeon E3-1240 v6
-
Kingston ValueRAM 16GB 2133MHz DDR4 ECC x4
Before failing to POST, it beeps 5 shorts and 1 long, indicating «No memory detected in system». It also displays «6=mrcReadMPRErr» on the screen.
I’ve tried reseating the card and tried both CPU and PCH PCI-E slots. I don’t want to try it in my existing production server, but I tried it in two desktop systems. The newer system gives the same result, a POST error code that indicates that no memory is installed. The older system (still has PCI slots) POSTs fine and I can go into the PERC configuration utility without issue. It shows MPT Firmware Revision 2.15.63.00-IR and Package Version 7.01.33.00.
I’d appreciate any input on how I should proceed.
Update 1
I flashed the device to IT mode but, unfortunately, it had no effect on the POSTing problem.
Update 2
The H310 tape mod actually worked, well mostly. It allowed the system to POST:
-
H310 mod on problematic H200 — 01
-
H310 mod on problematic H200 — 02
All is not perfect, however, it takes 3 minutes from the LSI copyright notice before the Initializing… & Ctrl-C prompts show, and then another 2 minutes after hitting Ctrl-C for the configuration utility to show. (And not just on the first boot after flashing.) I know these will be gone once I flash to IT mode, but I worry that this card might have problems. I’m unsure if I should trust it. Any thoughts?
Update 3
I’ve decided to try to return it to the seller and ordered another one from elsewhere. It just seems to be a problematic card. Thanks for the input all.
Update 4
A new H200 from a different seller arrived, and so far it’s doing the same thing! I’m really perplexed. I’m going to try the H310 tape mod and see what happens.
Update 5
With the H310 tape mod and flashed to IT mode P20, the device and connected drives are showing up in ESXi. I’m going to hook up the remaining drives and breakout cable and then setup the PCI passthrough and begin burn-in testing.
I’m not certain I trust this situation yet and I also worry a bit about the longevity of the tape mod, but I don’t have a lot of options unless I want to keep buying cards. I’ll report back one way or the other.
Update 6
I completed a full badblocks burn-in and SMART reported no errors. So I think the H200 + H310 tape mod + IT mode flash is working okay.
-
#1
All is now well!!!!! Turns out that the memory sticks were not properly seated. When I finally got them properly seated, everything is working perfectly. I always err on the side of using less force, but in this case, more force was the answer.
I have the following parts and am unable to boot the system.
Supermicro X11SSH-CTF-B LGA1151/ Intel C236/ DDR4/ SATA3&SAS3&USB3.0/ V&2GbE/ MicroATX Server Motherboard
Timetec Hynix IC 32GB KIT (2x16GB) DDR4 2666MHz PC4-21300 Unbuffered ECC 1.2V CL19 2Rx8 Dual Rank 288 Pin UDIMM Server Memory RAM Module Upgrade
Xeon E3-1230 v6
If I am reading everything properly, these parts should be compatible but when the system boots, I see the following on the monitor,
PEI — IPMI Initialization
then I hear 5 short beeps and one long beep that according to the users manual indicates a memory error
And the monitor reads
0X06 = mrcReadMPRErr
I have tried only one memory module and cleared the CMOS.
Is there an incompatibility that I am missing?
All Help Will Be Greatly Appreciated.
Thanks
Bob Ivey
Last edited: Jul 12, 2021
Specs:
-
Motherboard: Supermicro X11SSM (https://www.supermicro.com/en/products/motherboard/X11SSM)
-
CPU: Intel Xeon E3-1260V6 (https://ark.intel.com/content/www/us/en/ark/products/52271/intel-xeon-processor-e3-1230-8m-cache-3-20-ghz.html)
-
RAM: 2x16GB DDR4 2400MHz ECC UDIMM (https://www.ebay.com/itm/202102125201)
And for reference, here is the memory support section from motherboard quick-start guide: https://i.imgur.com/enW6zON.png
For my memory configuration (2x16gb) the recommended DIMM slots to be used are DIMMB2 and DIMMA2. When I first attempted booting with the RAM in this configuration, I was met with the memory error beep code from the motherboard and the following error in IPMI: 0x06=mrcReadMPRErr
.
Thinking that I maybe had some bad memory, I reduced my configuration to a single card in DIMMB2, and success! I was able to boot. I swapped that stick out for the other (same slot, DIMMB2) and was met with similar success. I then tried a single card in DIMMA2 and got the same mrcReadMPRErr
as before. I figured I would try a few more configurations, and when I slotted the RAM in DIMMB2 and DIMMB1, I was able to boot with the full 32 GB.
So my question is: is something wrong with the DIMM slots on my motherboard? By having my memory in this configuration, am I missing out on the memory interleaving that the quick start guide mentioned? If so, is this a big deal?
I am not planning on expanding beyond 32 GB of RAM (CPU only supports 32GB anyway), so if one of the DIMM slots is broken, then so be it, but I don’t want performance to be heavily impacted. Any suggestions/wisdom/knowledge would be appreciated! Thank you.
1 / 1 / 0 Регистрация: 10.10.2019 Сообщений: 11 |
|
1 |
|
18.03.2021, 16:20. Показов 12763. Ответов 11
Доброго времени суток. Есть сервер со следующей конфигурацией:
Проблема заключается в том,что при включении сервера на экране появляется логотип SuperMicro на белом фоне,внизу слева следуют надписи: Код PEI—IPMI Initialization... PEI—SB Initialization... (появляется на миллисекунду) PEI—Intel MRC Execution... (справа код 2F) После этого ничего не происходит. В чём может быть проблема? 0 |
4597 / 2260 / 459 Регистрация: 09.09.2017 Сообщений: 8,241 |
|
18.03.2021, 16:38 |
2 |
I_FarEvil_I, Не поддерживает мат. плата регистровую (буферизированную) память. Для проца и мат. платы заявлена только поддержка ECC-памяти (с коррекцией ошибок). 0 |
1 / 1 / 0 Регистрация: 10.10.2019 Сообщений: 11 |
|
18.03.2021, 16:39 [ТС] |
3 |
ibarg, то есть нужно идти покупать UDIMM? 0 |
4597 / 2260 / 459 Регистрация: 09.09.2017 Сообщений: 8,241 |
|
18.03.2021, 16:41 |
4 |
Решение
покупать UDIMM? По ходу да. 0 |
1 / 1 / 0 Регистрация: 10.10.2019 Сообщений: 11 |
|
18.03.2021, 16:47 [ТС] |
5 |
Хорошо, спасибо за информацию. В ближайшее время куплю UDIMM память, если будет подобное-напишу. 0 |
1376 / 508 / 99 Регистрация: 11.03.2015 Сообщений: 1,735 |
|
19.03.2021, 13:18 |
6 |
I_FarEvil_I, 1 |
0 / 0 / 0 Регистрация: 15.06.2021 Сообщений: 3 |
|
15.06.2021, 09:36 |
7 |
В итоге, с какой именно запустилось? 0 |
1 / 1 / 0 Регистрация: 10.10.2019 Сообщений: 11 |
|
15.06.2021, 12:08 [ТС] |
8 |
dompro, UDIMM ECC DDR4, у меня — Samsung M391A4G43MB1-CTDQY 1 |
0 / 0 / 0 Регистрация: 15.06.2021 Сообщений: 3 |
|
24.06.2021, 12:35 |
9 |
Попробовал Kingston KSM32ES8/8ME , та же ошибка. Это на 3200 частоты, но подстраивается под 2666. Но похоже плате нужно жестко конкретно 2666? 0 |
1 / 1 / 0 Регистрация: 10.10.2019 Сообщений: 11 |
|
24.06.2021, 13:23 [ТС] |
10 |
плате нужно жестко конкретно 2666? Да. 0 |
0 / 0 / 0 Регистрация: 15.06.2021 Сообщений: 3 |
|
06.07.2021, 13:17 |
11 |
Какая-то хрень, опять ждал пока доедет другая плашка, купил Samsung [M391A1K43BB2-CTD] 8 ГБ, поставил и то же самое. Может дело не в памяти? Уже двадцать раз пожалел что эту материнку выбрал. 0 |
1376 / 508 / 99 Регистрация: 11.03.2015 Сообщений: 1,735 |
|
12.07.2021, 13:01 |
12 |
dompro, Error code 2F means memory initialization. It is generated thru the BIOS. You may have memory issue. Please check your memory DIMMs and motherboard’s DIMM sockets. Скачайте мануал от материнки с этой страницы: 0 |
IT_Exp Эксперт 87844 / 49110 / 22898 Регистрация: 17.06.2006 Сообщений: 92,604 |
12.07.2021, 13:01 |
12 |
Wenn Du diese Anzeige nicht sehen willst, registriere Dich und/oder logge Dich ein.
Wenn Du diese Anzeige nicht sehen willst, registriere Dich und/oder logge Dich ein.
-
#7
es gehört etwas mehr zu einem PC als das Motherboard und alles könnte Fehler relevant sein
CPU
RAM
Netzeil
Grafik
…
einen CMOS Reset hast Du bereits durchgeführt?
den CPU Sockel hast Du mal mit einer Lupe geprüft? absolut nichts verbogen?
Zuletzt bearbeitet: 25.10.2018
-
#14
BIOS update über IPMI geht nur mit kostenpflichtigem Update
baue einen FreeDOS USB Stick mit Rufus und aktualisiere damit, eventuell verschwindet dann auch der Fehler
Speicher: Kingston KVR24E17S8/8MA ValueRAM Server Speicher (8GB, 2400MHz, DDR4 ECC CL17 DIMM, Micron A)
Zuletzt bearbeitet: 25.10.2018
-
#19
Zuletzt bearbeitet: 27.10.2018
HOW TO FIX INTERNAL ERROR 0X06 SYSTEM ERROR — YOUTUBE
Web Jul 27, 2019 How To Fix Internal Error 0x06 System Error — Solve Internal Error 0x06 System Error [Tutorial]Codex Internal Error 0x06 issues are caused by misconfigured s…
From youtube.com
Author MDTechVideos
Views 27.5K
FAQ ENTRY | ONLINE SUPPORT | SUPPORT — SUPER MICRO COMPUTER, INC.
Web Answer The STATUS BITS of offset 0x78 in the PWS-703P-1R power supply are as below: #7 Not used, default = 0 #6 Device is off due to PSON or for any reason (eg. Protection) …
From supermicro.com
0X06. C — MORE POINTERS ARRAYS AND STRINGS — YOUTUBE
Web #0x06. C — More pointers arrays and strings#alx-low_level_programmingLink to complete video: https://youtu.be/E5XZjPd-OXQ#youtube #alx #coding#learning#intra…
From youtube.com
0X06. C — MORE POINTERS, ARRAYS AND STRINGS QUIZ — YOUTUBE
Web 0x06. C — More pointers, arrays and strings QUIZS
From youtube.com
0X06 MORE POINTERS ARRAYS AND STRINGS — YOUTUBE
Web This video contains solution to the question on 0x06 more pointers, arrays and strings.please kindly subscribe to my channel and turn on notification button,…
From youtube.com
FAQ ENTRY | ONLINE SUPPORT | SUPPORT — SUPER MICRO COMPUTER, INC.
Web Answer Post code 02 means: AP initialization before microcode loading. Supposedly related to HW conflict for your system. Please keep minimum configuration with 1x E5-2600 …
From supermicro.com
FAQ ENTRY | ONLINE SUPPORT | SUPPORT — SUPER MICRO …
Web We are getting error code 0x06=mrcReadMPRErr on X11SSL-F during boot up when we are using 3 or more 16GB of memory with Intel SSD DC P3520 NVME. We are not …
From supermicro.com
FARMERS MARKET | WARRENTON, VA
Web Contact Us. Please contact the Town of Warrenton Community Development Department with any questions regarding the Farmers Market: Community Development. 21 Main …
From warrentonva.gov
FLYER | FOOD BASICS
Web Find Your Food Basics Flyer More about us Contact us Our products and private brands Food Basics Pharmacy Get inspired by our recipes Student Discount E-receipts …
From foodbasics.ca
HOME | FOOD BASICS
Web Find Your Food Basics Flyer More about us Contact us Our products and private brands Food Basics Pharmacy Get inspired by our recipes Student Discount E-receipts …
From foodbasics.ca
超微 X11SSH-F 开机报错(已解决)-CHIPHELL-非常论坛
Web 1.先确认BIOS是否最新,双面纯ECC内存如果主板厂没有优化,最多2条就不能开机 (本人在Zen3、X99上亲测过) 2.把CPU拆下来,看LGA针脚是否歪针 3.用橡皮擦把CPU、内存 …
From machbbs.com
MOBO ONLY BOOTS WITH NON-PREFERRED RAM ORDERING : …
Web When I first attempted booting with the RAM in this configuration, I was met with the memory error beep code from the motherboard and the following error in IPMI: …
From reddit.com
0X06. C — MORE POINTERS, ARRAYS AND STRINGS — GITHUB
Web A tag already exists with the provided branch name. Many Git commands accept both tag and branch names, so creating this branch may cause unexpected behavior.
From github.com
SOLVED — SUPERMICRO X11SSH-CTF BOOT PROBLEM
Web Feb 19, 2020 then I hear 5 short beeps and one long beep that according to the users manual indicates a memory error And the monitor reads 0X06 = mrcReadMPRErr I have …
From truenas.com
0X06. REGULAR EXPRESSION · GITHUB
Web Jan 9, 2020 0x06. Regular expression. Product Actions. Automate any workflow Packages. Host and manage packages Security. Find and fix vulnerabilities Codespaces. Instant …
From github.com
A BAKERY GAVE BLM ACTIVISTS FREE COFFEE. NOW COUNTERPROTESTERS …
Web Mar 10, 2023 A Va. bakery gave BLM activists free coffee. Then came the backlash. Red Truck Bakery in Warrenton, Va., is now at the center of a conflict between Black Lives …
From washingtonpost.com
ACIDIC FOODS: WHAT TO LIMIT OR AVOID — HEALTHLINE
Web Foods that are considered acidic generally have a pH level of 4.6 or lower. Foods that tend to cause more acidity in the body and that you may want to limit or avoid include ( 4 ): …
From healthline.com
THE 10 BEST WARRENTON FOOD DELIVERY & TAKEOUT — ORDER ONLINE …
Web Whether you’re in the mood for American Food delivery, Mexican Food delivery, or something else, find something to satisfy your cravings, from the places offering delivery …
From ubereats.com
DINE — EXPERIENCE OLD TOWN WARRENTON
Web Feb 28, 2023 Farm to table comfort food and local brews in Historic Digs. Claire’s At The Depot. 65 South Third Street, Warrenton, Virginia 20186. Website (540) 351-1616. …
From oldtownwarrenton.org
Перейти к контенту
-
#1
Hi, this is my first post connected with new hardware.
I’m starting to build up a server.
I have such a devices:
MB: SuperMicro X11SSL-F
CPU: e3-1230v6
RAM: Samsung 4x16GB 2400 UDIMM ECC.
I had build up the PC, run it and I hear 5 short beeps and one long.
Then I entered to the IMPI and I see following Hardware list.
which is completely different, because Now I have v6 cpu and only one Ram on the board.
Here is stated bios 2.0c, but on the other site there is an 2.1a
On monitor I see something like that:
0x09 mrc data time centering 1d error
What should I do?
-
#2
- place one stick of ram in slot DIMMA1
- reset your ipmi back to factory default
- reboot the system
-
#3
did it,
now there is other issue
the system works only with 2 memory slots occupied — so only 32GB ram.
If I put 3.rd or 4th ram stick the system can not boot.
I get such error exactly:
Code:
0x09=mrcDataTimeCentering1DErr
I can only occupy the 2 first slots from the top (black and blue)
-
#5
Are all four of the ram modules part#M391A2K43BB1-CRC ???
Test each stick (one at a time) in the first ram slot (if one of the
sticks fails to boot) you may have a bad stick of ram.
-
#6
Disable the jumpers of SMB to PCI Slots (JI2C1/JI2C2) — from 1-2 to 2-3 and all will be fine
DrKK
FreeNAS Generalissimo
-
#7
Disable the jumpers of SMB to PCI Slots (JI2C1/JI2C2) — from 1-2 to 2-3 and all will be fine
really. What does that do?
-
#8
This is due to hardware limitation as the result of SMBus address conflict between DIMMA1 and the PCIe devices
-
#9
This is due to hardware limitation as the result of SMBus address conflict between DIMMA1 and the PCIe devices
How do you arrive at that conclusion?
-
#10
my system (X11-SSM) had same problems with 4pcs of 16GB modules (beeps at startup, 0x09=mrcDataTimeCentering1DErr, etc). I got information from Supermicro support about hardware limitations for SSM/SSL/SSH mainboards. And after setting jumpers to disable SMBus — system can start normally, w/o beeps and with all 64GB.
Very easy to check, but i don’t know where is TS — yacenty
Last edited: May 13, 2018
-
#11
Interesting. I assume those DIMMs are not on the QVL?
-
#12
yes ) HPE with SK Hynix chips
-
#13
my system (X11-SSM) had same problems with 4pcs of 16GB modules (beeps at startup, 0x09=mrcDataTimeCentering1DErr, etc). I got information from Supermicro support about hardware limitations for SSM/SSL/SSH mainboards. And after setting jumpers to disable SMBus — system can start normally, w/o beeps and with all 64GB.
Very easy to check, but i don’t know where is TS — yacenty
RSA- I was having this exact issue whenever I tried putting in 4DIMMS… your post saved me a ton of wasted time and heartache!!! Thank you!!!!
-
#14
RSA- I was having this exact issue whenever I tried putting in 4DIMMS… your post saved me a ton of wasted time and heartache!!! Thank you!!!!
i’m really happy to help you
1 / 1 / 0 Регистрация: 10.10.2019 Сообщений: 9 |
|
1 |
|
18.03.2021, 16:20. Показов 11588. Ответов 11
Доброго времени суток. Есть сервер со следующей конфигурацией:
Проблема заключается в том,что при включении сервера на экране появляется логотип SuperMicro на белом фоне,внизу слева следуют надписи: Код PEI—IPMI Initialization... PEI—SB Initialization... (появляется на миллисекунду) PEI—Intel MRC Execution... (справа код 2F) После этого ничего не происходит. В чём может быть проблема?
__________________ 0 |
4448 / 2135 / 432 Регистрация: 09.09.2017 Сообщений: 7,742 |
|
18.03.2021, 16:38 |
2 |
I_FarEvil_I, Не поддерживает мат. плата регистровую (буферизированную) память. Для проца и мат. платы заявлена только поддержка ECC-памяти (с коррекцией ошибок). 0 |
1 / 1 / 0 Регистрация: 10.10.2019 Сообщений: 9 |
|
18.03.2021, 16:39 [ТС] |
3 |
ibarg, то есть нужно идти покупать UDIMM? 0 |
4448 / 2135 / 432 Регистрация: 09.09.2017 Сообщений: 7,742 |
|
18.03.2021, 16:41 |
4 |
покупать UDIMM? По ходу да. 0 |
1 / 1 / 0 Регистрация: 10.10.2019 Сообщений: 9 |
|
18.03.2021, 16:47 [ТС] |
5 |
Хорошо, спасибо за информацию. В ближайшее время куплю UDIMM память, если будет подобное-напишу. 0 |
1376 / 508 / 99 Регистрация: 11.03.2015 Сообщений: 1,735 |
|
19.03.2021, 13:18 |
6 |
I_FarEvil_I, 1 |
0 / 0 / 0 Регистрация: 15.06.2021 Сообщений: 3 |
|
15.06.2021, 09:36 |
7 |
В итоге, с какой именно запустилось? 0 |
1 / 1 / 0 Регистрация: 10.10.2019 Сообщений: 9 |
|
15.06.2021, 12:08 [ТС] |
8 |
dompro, UDIMM ECC DDR4, у меня — Samsung M391A4G43MB1-CTDQY 1 |
0 / 0 / 0 Регистрация: 15.06.2021 Сообщений: 3 |
|
24.06.2021, 12:35 |
9 |
Попробовал Kingston KSM32ES8/8ME , та же ошибка. Это на 3200 частоты, но подстраивается под 2666. Но похоже плате нужно жестко конкретно 2666? 0 |
1 / 1 / 0 Регистрация: 10.10.2019 Сообщений: 9 |
|
24.06.2021, 13:23 [ТС] |
10 |
плате нужно жестко конкретно 2666? Да. 0 |
0 / 0 / 0 Регистрация: 15.06.2021 Сообщений: 3 |
|
06.07.2021, 13:17 |
11 |
Какая-то хрень, опять ждал пока доедет другая плашка, купил Samsung [M391A1K43BB2-CTD] 8 ГБ, поставил и то же самое. Может дело не в памяти? Уже двадцать раз пожалел что эту материнку выбрал. 0 |
1376 / 508 / 99 Регистрация: 11.03.2015 Сообщений: 1,735 |
|
12.07.2021, 13:01 |
12 |
dompro, Error code 2F means memory initialization. It is generated thru the BIOS. You may have memory issue. Please check your memory DIMMs and motherboard’s DIMM sockets. Скачайте мануал от материнки с этой страницы: 0 |
IT_Exp Эксперт 87844 / 49110 / 22898 Регистрация: 17.06.2006 Сообщений: 92,604 |
12.07.2021, 13:01 |
12 |
I recently built a new server which I’ve been testing successfully without peripherals. I picked up a PERC H200 that I intend to flash to IT mode (but is currently in IR mode) that I intended to use for my HBA. Unfortunately, when I install the card, the system refuses to boot.
The relevant components of the system in question are:
-
Supermicro X11SSM-F (BIOS 2.0a)
-
Xeon E3-1240 v6
-
Kingston ValueRAM 16GB 2133MHz DDR4 ECC x4
Before failing to POST, it beeps 5 shorts and 1 long, indicating «No memory detected in system». It also displays «6=mrcReadMPRErr» on the screen.
I’ve tried reseating the card and tried both CPU and PCH PCI-E slots. I don’t want to try it in my existing production server, but I tried it in two desktop systems. The newer system gives the same result, a POST error code that indicates that no memory is installed. The older system (still has PCI slots) POSTs fine and I can go into the PERC configuration utility without issue. It shows MPT Firmware Revision 2.15.63.00-IR and Package Version 7.01.33.00.
I’d appreciate any input on how I should proceed.
Update 1
I flashed the device to IT mode but, unfortunately, it had no effect on the POSTing problem.
Update 2
The H310 tape mod actually worked, well mostly. It allowed the system to POST:
-
H310 mod on problematic H200 — 01
-
H310 mod on problematic H200 — 02
All is not perfect, however, it takes 3 minutes from the LSI copyright notice before the Initializing… & Ctrl-C prompts show, and then another 2 minutes after hitting Ctrl-C for the configuration utility to show. (And not just on the first boot after flashing.) I know these will be gone once I flash to IT mode, but I worry that this card might have problems. I’m unsure if I should trust it. Any thoughts?
Update 3
I’ve decided to try to return it to the seller and ordered another one from elsewhere. It just seems to be a problematic card. Thanks for the input all.
Update 4
A new H200 from a different seller arrived, and so far it’s doing the same thing! I’m really perplexed. I’m going to try the H310 tape mod and see what happens.
Update 5
With the H310 tape mod and flashed to IT mode P20, the device and connected drives are showing up in ESXi. I’m going to hook up the remaining drives and breakout cable and then setup the PCI passthrough and begin burn-in testing.
I’m not certain I trust this situation yet and I also worry a bit about the longevity of the tape mod, but I don’t have a lot of options unless I want to keep buying cards. I’ll report back one way or the other.
Update 6
I completed a full badblocks burn-in and SMART reported no errors. So I think the H200 + H310 tape mod + IT mode flash is working okay.
I recently built a new server which I’ve been testing successfully without peripherals. I picked up a PERC H200 that I intend to flash to IT mode (but is currently in IR mode) that I intended to use for my HBA. Unfortunately, when I install the card, the system refuses to boot.
The relevant components of the system in question are:
-
Supermicro X11SSM-F (BIOS 2.0a)
-
Xeon E3-1240 v6
-
Kingston ValueRAM 16GB 2133MHz DDR4 ECC x4
Before failing to POST, it beeps 5 shorts and 1 long, indicating «No memory detected in system». It also displays «6=mrcReadMPRErr» on the screen.
I’ve tried reseating the card and tried both CPU and PCH PCI-E slots. I don’t want to try it in my existing production server, but I tried it in two desktop systems. The newer system gives the same result, a POST error code that indicates that no memory is installed. The older system (still has PCI slots) POSTs fine and I can go into the PERC configuration utility without issue. It shows MPT Firmware Revision 2.15.63.00-IR and Package Version 7.01.33.00.
I’d appreciate any input on how I should proceed.
Update 1
I flashed the device to IT mode but, unfortunately, it had no effect on the POSTing problem.
Update 2
The H310 tape mod actually worked, well mostly. It allowed the system to POST:
-
H310 mod on problematic H200 — 01
-
H310 mod on problematic H200 — 02
All is not perfect, however, it takes 3 minutes from the LSI copyright notice before the Initializing… & Ctrl-C prompts show, and then another 2 minutes after hitting Ctrl-C for the configuration utility to show. (And not just on the first boot after flashing.) I know these will be gone once I flash to IT mode, but I worry that this card might have problems. I’m unsure if I should trust it. Any thoughts?
Update 3
I’ve decided to try to return it to the seller and ordered another one from elsewhere. It just seems to be a problematic card. Thanks for the input all.
Update 4
A new H200 from a different seller arrived, and so far it’s doing the same thing! I’m really perplexed. I’m going to try the H310 tape mod and see what happens.
Update 5
With the H310 tape mod and flashed to IT mode P20, the device and connected drives are showing up in ESXi. I’m going to hook up the remaining drives and breakout cable and then setup the PCI passthrough and begin burn-in testing.
I’m not certain I trust this situation yet and I also worry a bit about the longevity of the tape mod, but I don’t have a lot of options unless I want to keep buying cards. I’ll report back one way or the other.
Update 6
I completed a full badblocks burn-in and SMART reported no errors. So I think the H200 + H310 tape mod + IT mode flash is working okay.