NOTE: Execute the IIT diagnosis and then call NVM location [715-030] again (press the
Change Settings button) to check the value (diagnosis result).
Table 1 LED
Current value
Component Name
00
Not applicable (No errors)
01
LED Lamp PWB
02
CCD Lens Assembly
03
CCD Flexible Flat Cable
10
LED Lamp Flexible Flat Cable
12
IIT-ESS Video Cable
14
IIT-ESS I/O Cable
17
LVPS-IIT/Fax Power Cable (DC Harness)
4.
After replacing the appropriate parts, again change the value for NVM location [715-030]
to «1» and then execute «NVM Write».
5.
Check that the current value column becomes «000».
6.
If the problem persists after performing the above procedure, continue and check the fol-
lowing:
•
LED Lamp broken:
Component Control
•
Check the Flat Cable between the LED Lamp PWB
J723
for open circuits, short circuits, and poor contacts (especially, check whether
the Flat Cable was inserted in a skewed manner).
•
Check the Flat Cable between the CCD Lens Assembly
J710
for open circuits, short circuits, and poor contacts (especially, check whether
the Flat Cable was inserted in a skewed manner).
•
The coaxial cable between the IIT PWB
open circuit, short circuit, and poor contact
Status Indicator RAPs
062-380, 062-386
PL No.
—
PL 1.4
PL 1.2
PL 1.2
PL 1.4
PL 18.3
PL 18.3
PL 18.3
[062-002]
(PL
1.2)
P/J7001
and the IIT PWB
P/J700
and the IIT PWB
P/J7191
and the ESS PWB
P/J336
BUS Updated 12/2011
BSD-ON:
BSD 6.6 — Image Input
A CCD output error was detected when performing AOC.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Initial Actions
Check the light path for any obstacle, and the lamp, the lens, the mirror and the White Correct-
ing Plate for deterioration or contamination.
Procedure
1.
Turn the power ON and enter the Diag mode. Change the value for NVM location [715-
030] to «1» and then execute «NVM Write».
2.
A 3 or 4-digit number is displayed in the current value column.
3.
Check the upper 1 or 2 digits, or the lower 2 digits using the following table and replace
the appropriate parts.
Sample Display
•
110 (3-digit display):
LED Lamp PWB failure and LED Lamp Flexible Flat Cable is damaged or has poor
P/
contact.
(The first digit «1» in «110» is the upper digit, which indicates the LED Lamp PWB («0»
in «01» is not displayed). The lower 2 digits «10» indicates the LED Lamp Flexible Flat
P/
Cable.)
•
1000 (4-digit display):
The LED Lamp Flexible Flat Cable is damaged or has poor contact.
for
(The first 2 digits «10» in «1000» are the upper digits, which indicates the LED Lamp
Flexible Flat Cable. The lower 2 digits «00» indicates that nothing is applicable (no
failures).)
07/2011
2-780
Initial Issue
WorkCentre 5335 Family Service Documentation
Модератор: vetal
kartash » Пт июл 24, 2020 9:49 am
Никогда не встанут на колени, даже если заберут их в плен… Гордые и смелые тюлени… Ибо вовсе нет у них колен.
-
kartash
- Осматривается
-
- ICQ
- Персональный альбом
-
-
Xerox Phaser 6600 «Invalid Yellow» / «Неверный желтый»
kotya-potya в форуме Принтеры, МФУ, факсы, копиры формата A4
- 5
- 5689
3100
Пн ноя 18, 2019 8:24 pm
-
Xerox Phaser 6600 «Invalid Yellow» / «Неверный желтый»
-
-
Xerox WC 3119: «Замятие 1»
kokubenko в форуме Принтеры, МФУ, факсы, копиры формата A4
- 22
- 39494
kokubenko
Ср ноя 23, 2011 4:47 pm
-
Xerox WC 3119: «Замятие 1»
-
-
Xerox 3315 «слетела» FIX прошивка
tekknik в форуме Принтеры, МФУ, факсы, копиры формата A4
- 7
- 7246
tekknik
Пн июн 10, 2019 4:22 am
-
Xerox 3315 «слетела» FIX прошивка
-
-
прошил xerox 3160b прошивкой FIX_b2580_1010079.fls не прошил
Володья в форуме Принтеры, МФУ, факсы, копиры формата A4
- 8
- 12975
Володья
Сб апр 30, 2011 8:05 am
-
прошил xerox 3160b прошивкой FIX_b2580_1010079.fls не прошил
-
-
Xerox 3428 «Установите Картридж»
Roller-ch в форуме Принтеры, МФУ, факсы, копиры формата A4
- 6
- 9570
SeMi
Сб авг 27, 2011 6:42 pm
-
Xerox 3428 «Установите Картридж»
Вернуться в Принтеры, МФУ, факсы, копиры формата A4
Кто сейчас на форуме
Сейчас этот форум просматривают: нет зарегистрированных пользователей и гости: 49
062-371, 380, 386, 393 Lamp Illumination Fail RAP
BSD-ON: BSD 6.3 Document Illumination and Image Input
062-371 Insufficient light from Lamp detected in CCD (during white gradation correction/agc before scan starts)
062-380 Insufficient lamp brightness was detected when performing AGC.
062-386 A CCD output error was detected when performing AOC.
062-393 Write failure to the Shading Memory has occurred.
Initial Actions
WARNING: Ensure that the electricity to the machine is switched off while performing tasks that do not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause death or injury. Moving parts can cause injury.
Perform ADJ 60.5 Optics Cleaning Procedure.
Procedure
1. Check the ribbon cable between the ESS PWB and the lamp assembly. If necessary, install a new FFC LED cable assembly, PL 60.20 Item 10.
2. If the fault persists, install new components as necessary:
• Lamp assembly, PL 60.20 Item 9.
• ESS PWB, PL 3.10 Item 6.
**This RAP is from Xerox Service Manual. All brand names and trademarks are their respective owner’s property.**
You may be also interested in below toner and drum chip (CRUM) for Xerox VersaLink C7020, C7025, C7030, C7000.
Toner Chip (For North America and West Europe Region):
• 106R03741 106R03744 106R03743 106R03742
• 106R03757 106R03760 106R03759 106R03758
• 106R03737 106R03740 106R03739 106R03738
Toner Chip (For South America and East Europe Region):
• 106R03749 106R03752 106R03751 106R03750
• 106R03745 106R03748 106R03747 106R03746
• 106R03765 106R03768 106R03767 106R03766
Toner Chip (For Metered Machine):
• 106R03733 106R03736 106R03735 106R03734
Drum Chip:
• 113R00780 113R00782
Go to printers
r/printers
Inkjets, lasers, thermal, commercial and industrial printers.
We make printers suck less by promoting printer maintenance, troubleshooting and providing accurate recommendations.
Online
•
Xerox Workcentre 6515 error 062-380 & 062-386
Hey I have this printer and got both of these error codes. From my research it appears to be something with the scanner, possibly a lose connector or bad sensor.
From reading other posts it sounds like I may be able to order a new scanner module.
Also if anyone has a link to a service manual that tells me how to replace it, maybe I could use that to check for a lose connection.
062-371, 380, 386, 393 Lamp Illumination Fail RAP
BSD-ON: BSD 6.3 Document Illumination and Image Input
062-371 Insufficient light from Lamp detected in CCD (during white gradation correction/agc before scan starts)
062-380 Insufficient lamp brightness was detected when performing AGC.
062-386 A CCD output error was detected when performing AOC.
062-393 Write failure to the Shading Memory has occurred.
Initial Actions
WARNING: Ensure that the electricity to the machine is switched off while performing tasks that do not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause death or injury. Moving parts can cause injury.
Perform ADJ 60.5 Optics Cleaning Procedure.
Procedure
1. Check the ribbon cable between the ESS PWB and the lamp assembly. If necessary, install a new FFC LED cable assembly, PL 60.20 Item 10.
2. If the fault persists, install new components as necessary:
• Lamp assembly, PL 60.20 Item 9.
• ESS PWB, PL 3.10 Item 6.
**This RAP is from Xerox Service Manual. All brand names and trademarks are their respective owner’s property.**
You may be also interested in below toner and drum chip (CRUM) for Xerox VersaLink C7020, C7025, C7030, C7000.
Toner Chip (For North America and West Europe Region):
• 106R03741 106R03744 106R03743 106R03742
• 106R03757 106R03760 106R03759 106R03758
• 106R03737 106R03740 106R03739 106R03738
Toner Chip (For South America and East Europe Region):
• 106R03749 106R03752 106R03751 106R03750
• 106R03745 106R03748 106R03747 106R03746
• 106R03765 106R03768 106R03767 106R03766
Toner Chip (For Metered Machine):
• 106R03733 106R03736 106R03735 106R03734
Drum Chip:
• 113R00780 113R00782
Модератор: vetal
kartash » Пт июл 24, 2020 9:49 am
Никогда не встанут на колени, даже если заберут их в плен… Гордые и смелые тюлени… Ибо вовсе нет у них колен.
-
kartash
- Осматривается
-
- ICQ
- Персональный альбом
-
-
Xerox Phaser 6600 «Invalid Yellow» / «Неверный желтый»
kotya-potya в форуме Принтеры, МФУ, факсы, копиры формата A4
- 5
- 5928
3100
Пн ноя 18, 2019 8:24 pm
-
Xerox Phaser 6600 «Invalid Yellow» / «Неверный желтый»
-
-
Xerox WC 3119: «Замятие 1»
kokubenko в форуме Принтеры, МФУ, факсы, копиры формата A4
- 22
- 39999
kokubenko
Ср ноя 23, 2011 4:47 pm
-
Xerox WC 3119: «Замятие 1»
-
-
прошил xerox 3160b прошивкой FIX_b2580_1010079.fls не прошил
Володья в форуме Принтеры, МФУ, факсы, копиры формата A4
- 8
- 13148
Володья
Сб апр 30, 2011 8:05 am
-
прошил xerox 3160b прошивкой FIX_b2580_1010079.fls не прошил
-
-
«Неисправность» финишера Xerox 7556
v1684 в форуме Принтеры, МФУ, копиры формата A3
- 21
- 13709
v1684
Ср сен 19, 2018 4:44 pm
-
«Неисправность» финишера Xerox 7556
-
-
Xerox 3428 «Установите Картридж»
Roller-ch в форуме Принтеры, МФУ, факсы, копиры формата A4
- 6
- 9733
SeMi
Сб авг 27, 2011 6:42 pm
-
Xerox 3428 «Установите Картридж»
Вернуться в Принтеры, МФУ, факсы, копиры формата A4
Кто сейчас на форуме
Сейчас этот форум просматривают: нет зарегистрированных пользователей и гости: 50
NOTE: Execute the IIT diagnosis and then call NVM location [715-030] again (press the
Change Settings button) to check the value (diagnosis result).
Table 1 LED
Current value
Component Name
00
Not applicable (No errors)
01
LED Lamp PWB
02
CCD Lens Assembly
03
CCD Flexible Flat Cable
10
LED Lamp Flexible Flat Cable
12
IIT-ESS Video Cable
14
IIT-ESS I/O Cable
17
LVPS-IIT/Fax Power Cable (DC Harness)
4.
After replacing the appropriate parts, again change the value for NVM location [715-030]
to «1» and then execute «NVM Write».
5.
Check that the current value column becomes «000».
6.
If the problem persists after performing the above procedure, continue and check the fol-
lowing:
•
LED Lamp broken:
Component Control
•
Check the Flat Cable between the LED Lamp PWB
J723
for open circuits, short circuits, and poor contacts (especially, check whether
the Flat Cable was inserted in a skewed manner).
•
Check the Flat Cable between the CCD Lens Assembly
J710
for open circuits, short circuits, and poor contacts (especially, check whether
the Flat Cable was inserted in a skewed manner).
•
The coaxial cable between the IIT PWB
open circuit, short circuit, and poor contact
Status Indicator RAPs
062-380, 062-386
PL No.
—
PL 1.4
PL 1.2
PL 1.2
PL 1.4
PL 18.3
PL 18.3
PL 18.3
[062-002]
(PL
1.2)
P/J7001
and the IIT PWB
P/J700
and the IIT PWB
P/J7191
and the ESS PWB
P/J336
BUS Updated 12/2011
BSD-ON:
BSD 6.6 — Image Input
A CCD output error was detected when performing AOC.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Initial Actions
Check the light path for any obstacle, and the lamp, the lens, the mirror and the White Correct-
ing Plate for deterioration or contamination.
Procedure
1.
Turn the power ON and enter the Diag mode. Change the value for NVM location [715-
030] to «1» and then execute «NVM Write».
2.
A 3 or 4-digit number is displayed in the current value column.
3.
Check the upper 1 or 2 digits, or the lower 2 digits using the following table and replace
the appropriate parts.
Sample Display
•
110 (3-digit display):
LED Lamp PWB failure and LED Lamp Flexible Flat Cable is damaged or has poor
P/
contact.
(The first digit «1» in «110» is the upper digit, which indicates the LED Lamp PWB («0»
in «01» is not displayed). The lower 2 digits «10» indicates the LED Lamp Flexible Flat
P/
Cable.)
•
1000 (4-digit display):
The LED Lamp Flexible Flat Cable is damaged or has poor contact.
for
(The first 2 digits «10» in «1000» are the upper digits, which indicates the LED Lamp
Flexible Flat Cable. The lower 2 digits «00» indicates that nothing is applicable (no
failures).)
07/2011
2-780
Initial Issue
WorkCentre 5335 Family Service Documentation